Accuracy of vertical radial plume mapping technique in measuring lagoon gas emissions.

نویسندگان

  • Maialen Viguria
  • Kyoung S Ro
  • Kenneth C Stone
  • Melvin H Johnson
چکیده

UNLABELLED Recently, the U.S. Environmental Protection Agency (EPA) posted a ground-based optical remote sensing method on its Web site called Other Test Method (OTM) 10 for measuring fugitive gas emission flux from area sources such as closed landfills. The OTM 10 utilizes the vertical radial plume mapping (VRPM) technique to calculate fugitive gas emission mass rates based on measured wind speed profiles and path-integrated gas concentrations (PICs). This study evaluates the accuracy of the VRPM technique in measuring gas emission from animal waste treatment lagoons. A field trial was designed to evaluate the accuracy of the VRPM technique. Control releases of methane (CH4) were made from a 45 m×45 m floating perforated pipe network located on an irrigation pond that resembled typical treatment lagoon environments. The accuracy of the VRPM technique was expressed by the ratio of the calculated emission rates (QVRPM) to actual emission rates (Q). Under an ideal condition of having mean wind directions mostly normal to a downwind vertical plane, the average VRPM accuracy was 0.77±0.32. However, when mean wind direction was mostly not normal to the downwind vertical plane, the emission plume was not adequately captured resulting in lower accuracies. The accuracies of these nonideal wind conditions could be significantly improved if we relaxed the VRPM wind direction criteria and combined the emission rates determined from two adjacent downwind vertical planes surrounding the lagoon. With this modification, the VRPM accuracy improved to 0.97±0.44, whereas the number of valid data sets also increased from 113 to 186. IMPLICATIONS The need for developing accurate and feasible measuring techniques for fugitive gas emission from animal waste lagoons is vital for livestock gas inventories and implementation of mitigation strategies. This field lagoon gas emission study demonstrated that the EPA's vertical radial plume mapping (VRPM) technique can be used to accurately measure lagoon gas emission with two downwind vertical concentration planes surrounding the lagoon.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring Trace Gas Emission from Multi-Distributed Sources Using Vertical Radial Plume Mapping (VRPM) and Backward Lagrangian Stochastic (bLS) Techniques

Two micrometeorological techniques for measuring trace gas emission rates from distributed area sources were evaluated using a variety of synthetic area sources. The vertical radial plume mapping (VRPM) and the backward Lagrangian stochastic (bLS) techniques with an open-path optical spectroscopic sensor were evaluated for relative accuracy for multiple emission-source and sensor configurations...

متن کامل

Path Integrated Optical Remote Sensing technique to estimate ammonia and methane emissions from CAFOs

Abstract. The U.S. EPA recently demonstrated that the open-path optical remote sensing technology could be used to identify hot spots and estimate mass flux of fugitive gases from closed landfills. The objective of this research was to validate this technology for estimating ammonia and methane emission from concentrated animal feeding operations (CAFOs). The technology utilizes the vertical ra...

متن کامل

Comparison of first-order-decay modeled and actual field measured municipal solid waste landfill methane data.

The first-order decay (FOD) model is widely used to estimate landfill gas generation for emissions inventories, life cycle assessments, and regulation. The FOD model has inherent uncertainty due to underlying uncertainty in model parameters and a lack of opportunities to validate it with complete field-scale landfill data sets. The objectives of this paper were to estimate methane generation, f...

متن کامل

Measurement of greenhouse gas emissions from agricultural sites using open-path optical remote sensing method.

Improved characterization of distributed emission sources of greenhouse gases such as methane from concentrated animal feeding operations require more accurate methods. One promising method is recently used by the USEPA. It employs a vertical radial plume mapping (VRPM) algorithm using optical remote sensing techniques. We evaluated this method to estimate emission rates from simulated distribu...

متن کامل

Atmospheric tomography: a Bayesian inversion technique for determining the rate and location of fugitive emissions.

A Bayesian inversion technique to determine the location and strength of trace gas emissions from a point source in open air is presented. It was tested using atmospheric measurements of N(2)O and CO(2) released at known rates from a source located within an array of eight evenly spaced sampling points on a 20-m radius circle. The analysis requires knowledge of concentration enhancement downwin...