[Diagnostic yield of pancreatic percutaneous puncture depending on the size of the lesion].

نویسندگان

  • Carlos Fortea-Sanchis
  • Luis Gómez-Quiles
  • David Martínez-Ramos
  • Javier Escrig Sos
  • Gabriel Alejandro Paiva-Coronel
  • Raquel Queralt-Martín
  • Álvaro Villarín-Rodríguez
  • Laura Granel-Villach
  • José Luis Salvador-Sanchis
چکیده

INTRODUCTION The aim of the present study was to study the diagnostic efficacy of the percutaneous puncture of pancreatic tissue. MATERIAL AND METHODS A retrospective study was conducted on patients with suspicion of pancreatic neoplasm, and with a percutaneous biopsy of pancreatic tissue, from 2000 to 2011. For the statistical comparative analysis, the sample was stratified by tumour size: ≤ 3cm and > 3cm. RESULTS A total of 90 biopsies were performed. Pancreatic neoplasm diagnosis was made in 47 cases (52%), with 16 false negatives (18%), no false positives, and chronic pancreatitis in 24 cases (27%). The efficacy of the test results were: an overall sensitivity of 75% (95% CI: 62%-85%), a specificity of 100% (95% CI: 87%-100%), a positive predictive value of 100% (95% CI: 92%-100%), and a negative predictive value of 63% (95% CI: 46%-77%). For tumour sizes ≤ 3cm the sensitivity was 70% (95% CI: 45%-88%), with a specificity of 100% (95% CI 66%-100%), a positive predictive value of 100% (95% CI: 76%-100%, and a negative predictive value 60% (95% CI: 32%-83%). For tumours greater than 3cm, the sensitivity was 88% (95% CI: 70%-98%), the specificity was 100% (95% CI: 75%-100%), with a positive predictive value of 100% (95% CI: 85%-100%) and a negative predictive value of 81% (95% CI: 54%-96%). CONCLUSIONS Pancreatic percutaneous biopsy efficacy was strongly determined by lesion size. For tumour sizes less than 3cm, the sensitivity and negative predictive value are unacceptably low, as negative results would not reliable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective randomized study of the difference in diagnostic yield between endoscopic ultrasound-guided fine-needle aspiration (EUSFNA) needles with and without a side port in pancreatic masses

BACKGROUND AND STUDY AIMS Two 22G needles with similar designs, apart from the absence (A) or presence of a side port (B), are available for endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA). The side port was designed to increase diagnostic yield but this advantage was unproven. This study evaluated the difference in diagnostic yield between both needles in pancreatic masses. P...

متن کامل

Approach to undiagnosed exudative pleural effusion: the diagnostic yield of blind pleural biopsy

Background: Blind percutaneous pleural biopsy has traditionally been performed to investigate the etiology of exudative pleural effusion in which the initial thoracocentesis has been non- diagnostic. In view of the increasing use of image-guided and thoracoscopic pleural biopsies, this study examined the role of blind Abrams pleural biopsy in the investigation of the exudative pleural effusion ...

متن کامل

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

بررسی ارزشمند بودن بیوپسی عضلانی به روش بسته‌ با سوزن در تشخیص بیماریهای التهابی عضله

ABSTRACT To determine the usefulness of a method of percutaneous needle muscle biopsy in patients with suspected idiopathic inflammatory Myopathy. The yield of percutaneous needle muscle biopsy was studied in 15 patients during 1997-2000 who were hospitalized in Hazrat Rasool Akram hospital. A diagnosis of idiopathic inflammatory myopathy was confirmed histopathologically in 8 patients...

متن کامل

A Prospective Comparison of EUS-Guided FNA Using 25-Gauge and 22-Gauge Needles

BACKGROUND AND AIMS There are limited data on the differences in diagnostic yield between 25-gauge and 22-gauge EUS-FNA needles. This prospective study compared the difference in diagnostic yield between a 22-gauge and a 25-gauge needle when performing EUS-FNA. METHODS Forty-three patients with intraluminal or extraluminal mass lesions and/or lymphadenopathy were enrolled prospectively. EUS-F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cirugia espanola

دوره 91 6  شماره 

صفحات  -

تاریخ انتشار 2013