Phasic coronary blood flow pattern during a continuous flow left ventricular assist support.

نویسندگان

  • Yoshio Ootaki
  • Keiji Kamohara
  • Masatoshi Akiyama
  • Firas Zahr
  • Michael W Kopcak
  • Raymond Dessoffy
  • Kiyotaka Fukamachi
چکیده

OBJECTIVE Continuous flow left ventricular assist devices (LVADs) have been introduced and tested as a bridge to heart transplantation, bridge to recovery, and destination therapy, and several studies have been conducted to assess the physiologic effects of continuous flow LVADs. However, the effect of reduced pulsatility on the phasic coronary blood flow pattern is unknown. The aim of this study was to investigate the phasic coronary blood flow patterns during continuous flow LVAD support. METHODS Phasic coronary blood flow patterns and hemodynamic data were analyzed using three flow probes placed around the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), and the right coronary artery (RCA) in 16 pigs before and after initiating the LVAD support with or without creating LAD stenosis. RESULTS The total coronary blood flow (TCBF, 112.8+/-31.4 mL/min) gradually decreased when the continuous flow LVAD support increased to 2.0 L/min (110.7+/-29.0 mL/min, P = 0.571), 2.5 L/min (103.7+/-26.1 mL/min, P = 0.079), and 3.0 L/min (101.5+/-27.2 mL/min, P = 0.027) because of decreases in LAD flow and LCX flow. LVAD support caused decrease in systolic and peak systolic LAD flow, LCX flow, and RCA flow, whereas diastolic RCA flow increased. In the presence of LAD stenosis, the TCBF (97.7+/-36.1 mL/min) decreased when the continuous flow LVAD support increased to 2.0 L/min (83.9+/-22.1 mL/min, P = 0.029), 2.5 L/min (83.2+/-25.2 mL/min, P = 0.012), and 3.0 L/min (87.6+/-23.4 mL/min, P = 0.005) because of decreases in LCX flow. CONCLUSION Use of a continuous flow LVAD decreased TCBF, LAD flow, and LCX flow secondary to reduced systolic LAD flow and LCX flow, and decreased TCBF and LCX flow in the presence of LAD stenosis. These findings are potentially relevant to understanding the physiology of myocardial blood perfusion during continuous flow LVAD support especially in patients with coronary artery disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phasic coronary blood flow velocity in intramural and epicardial coronary arteries.

Knowledge concerning phasic coronary blood flow is based primarily on measurements obtained from epicardial coronary arteries, which, in part, function as capacitors. If present, epicardial capacitance effects could obscure the dynamic nature of phasic intramyocardial perfusion. To analyze this effect of epicardial capacitance, we simultaneously measured coronary blood flow velocity in an epica...

متن کامل

Phasic right coronary artery blood flow in conscious dogs with normal and elevated right ventricular pressures.

We studied phasic right coronary blood flow in well trained normal dogs and dogs with pulmonic stenosis. We installed electromagnetic flow transducers and pressure tubes under anesthesia to monitor right coronary blood flow, cardiac output, central aortic blood pressure, and right ventribular pressure. In normotensive dogs, systolic flow amplitude equaled early diastolic flow levels. The ratio ...

متن کامل

Successful thrombectomy for acute coronary thromboembolism during Heartmate II ventricular support.

Complications of hemostasis account for the most common adverse events during continuous-flow ventricular assist device support for advanced heart failure. Successful management of acute coronary thromboembolism during HeartMateII device support has not been described in the literature. We present a case of acute coronary thromboembolism of the left main trunk associated with angina and ventric...

متن کامل

A mathematical model to evaluate control strategies for mechanical circulatory support.

Continuous flow ventricular assist devices (VADs) for mechanical circulatory support (MCS) are generally smaller and believed to be more reliable than pulsatile VADs. However, regarding continuous flow, there are concerns about the decreased pulsatility and ventricular unloading. Moreover, pulsatile VADs offer a wider range in control strategies. For this reason, we used a computer model to eva...

متن کامل

Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device.

BACKGROUND The effects of continuous blood flow and reduced pulsatility on major organ function have not been studied in detail. METHODS AND RESULTS We evaluated renal (creatinine and blood urea nitrogen) and hepatic (aspartate transaminase, alanine transaminase, and total bilirubin) function in 309 (235 male, 74 female) advanced heart failure patients who had been supported with the HeartMat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2005