Reduced push forces accompany device use during sliding transfers of seated subjects.

نویسندگان

  • P Grevelding
  • R W Bohannon
چکیده

PURPOSE Research verifying the ability of various devices to reduce the forces required for transfers is virtually nonexistent. Therefore, we compared the push forces required to move passive seated subjects across a horizontal surface when four different methods were employed. SUBJECTS 10 men and 14 women (weight 49.1-96.8 kg) served as subjects. METHODS AND MATERIALS Passive subjects were moved horizontally across a treatment table that had a vinyl-covered foam mat on top. They sat either directly on the mat or on a vinyl sliding board (Ross Easy Glide), on a fabric tube (Ross Mini-Slide), or on a fabric tube on top of a sliding board on top of the mat. Subjects were pushed horizontally by each of the two authors via a hand-held dynamometer that was placed over their greater trochanter. ANALYSES To examine interrater reliability of push forces, intraclass correlation coefficients (ICCs) were calculated for each transfer method using the two authors' measurements. Validity was confirmed using Pearson correlations to test the relationship between subjects' weights and the forces required to push them. A repeated measures analysis of variance (ANOVA) and pair-wise post hoc tests were used to compare the forces associated with the four methods. RESULTS The ICCs for push forces ranged from 0.77 to 0.91 depending on the transfer method. The push forces associated with the four transfer methods (no device=200.7+/-40.8 N, sliding board=120.5+/-27.7 N, fabric tube=105.8+/-26.1 N, fabric tube and sliding board=84.2+/-13.4 N,) differed significantly (F=273.9, p<0.001). CONCLUSIONS This study demonstrates that assistive devices can greatly reduce the forces required to move seated subjects horizontally. The sliding board and the fabric tube were most effective when used together. Such devices have the potential to make transfers easier for individuals performing seated transfers and to reduce the risk of injury among individuals assisting them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cytoplasmic dynein pushes the cytoskeletal meshwork forward during axonal elongation.

During development, neurons send out axonal processes that can reach lengths hundreds of times longer than the diameter of their cell bodies. Recent studies indicate that en masse microtubule translocation is a significant mechanism underlying axonal elongation, but how cellular forces drive this process is unknown. Cytoplasmic dynein generates forces on microtubules in axons to power their mov...

متن کامل

Difference in force direction during propulsion between subjects with different push-off locations

It could be hypothesized that when walking in a linear direction, the most efficient strategy would be to focus the force created by the push-off in the absolute opposite direction to the direction of propulsion. Forces in a medial or lateral direction could then be considered as loss of efficiency since these forces do not create movement in the intended direction. The aim of this study was to...

متن کامل

Cardiac autonomic responses after resistance exercise in treated hypertensive subjects

The aim of this study was to assess and to compare heart rate variability (HRV) after resistance exercise (RE) in treated hypertensive and normotensive subjects. Nine hypertensive men [HT: 58.0 ± 7.7 years, systolic blood pressure (SBP) = 133.6 ± 6.5 mmHg, diastolic blood pressure (DBP) = 87.3 ± 8.1 mmHg; under antihypertensive treatment] and 11 normotensive men (NT: 57.1 ± 6.0 years, SBP = 127...

متن کامل

ترکیب استفاده همزمان از بریس زانو و گوه خارجی بر طیف فرکانس نیروی عکس العمل زمین در بیماران مبتلا به استئوآرتریت زانو

 Aims and background:  The aim of this study was to determine the effects of isolated and combined use of valgus knee braces and lateral wedge foot orthotics on the frequency spectrum of ground reaction forces generated in the knee by the gait of patients with knee osteoarthritis. Materials and methods: 24 males (age: 62.1 ± 2.0 years( with varus knee malalignment and symptomatic medial compart...

متن کامل

Advanced Liquid-Free, Piezoresistive, SOI-Based Pressure Sensors for Measurements in Harsh Environments

In this paper we present and discuss two innovative liquid-free SOI sensors for pressure measurements in harsh environments. The sensors are capable of measuring pressures at high temperatures. In both concepts media separation is realized using a steel membrane. The two concepts represent two different strategies for packaging of devices for use in harsh environments and at high temperatures. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2001