A Comparison Study of Single-Echo Susceptibility Weighted Imaging and Combined Multi-Echo Susceptibility Weighted Imaging in Visualizing Asymmetric Medullary Veins in Stroke Patients

نویسندگان

  • Chao Wang
  • Tiantian Qiu
  • Ruirui Song
  • Yerfan Jiaerken
  • Linglin Yang
  • Shaoze Wang
  • Minming Zhang
  • Xinfeng Yu
چکیده

BACKGROUND Asymmetric medullary veins (AMV) are frequently observed in stroke patients and single-echo susceptibility weighted imaging (SWIs) is the main technique in detecting AMV. Our study aimed to investigate which echo time (TE) on single-echo susceptibility is the optimal echo for visualizing AMV and to compare the ability in detecting AMV in stroke patients between SWIs and multi-echo susceptibility weighted imaging (SWIc). MATERIALS AND METHODS Twenty patients with middle cerebral artery stroke were included. SWI was acquired by using a multi-echo gradient-echo sequence with six echoes ranging from 5 ms to 35.240 ms. Three different echoes of SWIs including SWIs1 (TE = 23.144 ms), SWIs2 (TE = 29.192 ms) and SWIs3 (TE = 35.240 ms) were reconstructed. SWIc was averaged using the three echoes of SWIs. Image quality and venous contrast of medullary veins were compared between SWIs and SWIc using peak signal-to-noise ratio (PSNR), mean opinion score (MOS), contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). The presence of AMV was evaluated in each SWIs (1-3) and SWIc. RESULTS SWIs2 had the highest PSNR, MOS and CNR and SWIs1 had the highest SNR among three different echoes of SWIs. No significant difference was found in SNR between SWIs1 and SWIs2. PSNR, MOS and CNR in SWIc were significantly increased by 27.9%, 28.2% and 17.2% compared with SWIs2 and SNR in SWIc was significantly increased by 32.4% compared with SWIs1. 55% of patients with AMV were detected in SWIs2, SWIs3 and SWIc, while 50% AMV were found in SWIs1. CONCLUSIONS SWIs using TE around 29ms was optimal in visualizing AMV. SWIc could improve image quality and venous contrast, but was equal to SWIs using a relative long TE in evaluating AMV. These results provide the technique basis for further research of AMV in stroke.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Turbo spin-echo diffusion-weighted MR of ischemic stroke.

PURPOSE Our objective was to determine whether a multisection technique, diffusion-weighted half-Fourier single-shot turbo spin-echo (HASTE) imaging, can compensate for the drawbacks common to other diffusion-weighted techniques; specifically, the need for echo-planar technology and the presence of susceptibility artifacts in areas close to the skull base. METHODS Forty subjects who were refe...

متن کامل

MRI features of intracerebral hemorrhage within 2 hours from symptom onset.

BACKGROUND AND PURPOSE MRI has been increasingly used in the evaluation of acute stroke patients. However, MRI must be able to detect early hemorrhage to be the only imaging screen used before treatment such as thrombolysis. Susceptibility-weighted imaging, an echo-planar T2* sequence, can show intracerebral hemorrhage (ICH) in patients imaged between 2.5 and 5 hours from symptom onset. It is u...

متن کامل

Hematoma volume measurement in gradient echo MRI using quantitative susceptibility mapping.

BACKGROUND AND PURPOSE A novel quantitative susceptibility mapping (QSM) processing technology has been developed to map tissue susceptibility property without blooming artifacts. We hypothesize that hematoma volume measurement on QSM is independent of imaging parameters, eliminating its echo time dependence on gradient echo MRI. METHODS Gradient echo MRI of 16 patients with intracerebral hem...

متن کامل

Ultrafast in vivo diffusion imaging of stroke at 21.1 T by spatiotemporal encoding.

PURPOSE This study quantifies in vivo ischemic stroke brain injuries in rats using ultrahigh-field single-scan MRI methods to assess variations in apparent diffusion coefficients (ADCs). METHODS Magnitude and diffusion-weighted spatiotemporally encoded imaging sequences were implemented on a 21.1 T imaging system, and compared with spin-echo and echo-planar imaging diffusion-weighted imaging ...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016