Elevated serum concentrations of cardiac troponin T in acute allograft rejection after human heart transplantation.
نویسندگان
چکیده
OBJECTIVES This study evaluates the concept and diagnostic efficacy of using serum troponin T for the detection of cardiac graft rejection. BACKGROUND Cardiac troponin T is a cardiospecific myofibrillar protein, which is only detectable in the circulation after cardiac myocyte damage. It might be expected to be released during acute heart allograft rejection, allowing noninvasive rejection diagnosis. METHODS In 35 control subjects and in 422 samples from 95 clinically unremarkable heart allograft recipients more than 3 months postoperatively, troponin T serum concentrations were compared to the histological grade of acute graft rejection in concurrent endomyocardial biopsies. RESULTS Mean troponin T serum concentrations were identical in control subjects (23.2 +/- 1.4 ng/liter) and in heart transplant recipients without graft rejection (International Society for Heart and Lung Transplantation [ISHLT] grade 0; 22.4 +/- 1.7 ng/liter). Mean troponin T concentrations increased in parallel with the severity of graft rejection (ISHLT grade 1: 27.8 +/- 1.8 ng/liter; grade 2: 33.2 +/- 2.7 ng/liter; grade 3A: 54.6 +/- 6.5 ng/liter; grade 3B and 4: 105.4 +/- 53.7 ng/liter; p < 0.001 for grades 3 and 4 vs. grades 0 and 1). The proportion of positive samples also increased in parallel with rejection severity, reaching 100% in rejections of grade 3B and 4. Sensitivity and specificity for the detection of significant graft rejection (ISHLT grade 3/4) were 80.4% and 61.8%, respectively. The negative predictive value was most remarkable with 96.2%. Intraindividual longitudinal analysis of troponin T levels and biopsy results in 15 patients during long-term follow-up confirmed these findings. CONCLUSIONS The present data demonstrate that acute allograft rejection after human heart transplantation is often associated with increased serum concentrations of troponin T. All cases of serious forms of graft rejection would have been detected before the development of clinical symptoms. Measurement of troponin T levels may become a useful ancillary parameter for noninvasive rejection diagnosis, being most valuable in the exclusion of severe cardiac graft rejection.
منابع مشابه
High-sensitivity cardiac troponin I assay to screen for acute rejection in patients with heart transplant.
BACKGROUND A noninvasive biomarker that could accurately diagnose acute rejection (AR) in heart transplant recipients could obviate the need for surveillance endomyocardial biopsies. We assessed the performance metrics of a novel high-sensitivity cardiac troponin I (cTnI) assay for this purpose. METHODS AND RESULTS Stored serum samples were retrospectively matched to endomyocardial biopsies i...
متن کاملEvaluation of CXCL9 and CXCL10 as circulating biomarkers of human cardiac allograft rejection
BACKGROUND Cardiac allograft rejection remains a significant clinical problem in the early phase after heart transplantation and requires frequent surveillance with endomyocardial biopsy. However, this is an invasive procedure, which is unpleasant for the patient and carries a certain risk. Therefore, a sensitive non-invasive biomarker of acute rejection would be desirable. METHODS Endomyocar...
متن کاملComparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation
Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...
متن کاملCASE REPORT Reversible left ventricular dysfunction associated with raised troponin I after subarachnoid haemorrhage does not preclude successful heart transplantation
Transient abnormalities in ECGs, echocardiograms, and cardiac enzymes have been described in the acute setting of subarachnoid haemorrhage. In addition, left ventricular dysfunction has been reported at the time of brain death. A patient with an acute subarachnoid haemorrhage who presented with raised troponin I (TnI) concentrations and diVuse left ventricular dysfunction is described. After de...
متن کاملTroponin T release after heart transplantation.
BACKGROUND For the diagnosis of myocardial cell damage the measurement of the serum concentrations of myofibrillar antigens has several potential advantages over the assessment of traditional serological markers. These include the expression of myofibrillar antigens as cardiospecific isoforms and their high intracellular concentrations. Recently a sensitive and specific enzyme immunoassay for c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1998