Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria.
نویسندگان
چکیده
Periprosthetic osteolysis is a serious problem that limits long-term survival of total hip arthroplasty. Ceramics have been introduced as a joint surface material to reduce osteolysis due to wear particles. The aim of this study is to investigate the biological reaction of ceramic particles on murine calvarial bone, in comparison with polyethylene and titanium particles. Sixty CL/BL6 mice were divided into five groups according to the materials implanted onto the murine calvariae: control, Al(2)O(3), ZrO(2), high-density polyethylene (HDP) and Ti6Al4V. One week after the implantation, each calvarial tissue was dissected and the release of proinflammatory mediators (IL-1beta, IL-6, TNF-alpha) and bone resorption were assessed. The particles of HDP and Ti6Al4V induced three and two times larger osteolytic lesions than the control, respectively. The levels of IL-1beta and IL-6 were significantly elevated in the medium subcultured with the calvariae of HDP and Ti6Al4V groups. Any particle type did not increase the levels of TNF-alpha. There were no significant differences observed in the levels of proinflammatory mediators or osteolytic area among Al(2)O(3), ZrO(2) and control groups. The inflammatory response and bone resorption induced by ceramic particles were much smaller than those induced by HDP and Ti6Al4V. These biological features suggest the biocompatibility of ceramics as a joint surface material for artificial joints.
منابع مشابه
Biocompatibility Evaluation of Ti–15Al–33Nb(at%) and Ti–21Al–29Nb(at%)
In this work the biocompatibility of two vanadium-free Ti–Al–Nb alloys, Ti–15Al–33Nb and Ti–21Al–29Nb, was evaluated and compared to that for commercially pure titanium (CP Ti) and alumina (Al2O3). Fine particles were milled from sheet-processed material and implanted onto mice calvaria using an established animal model. Various stains, including methylene blue/acid fuchsin, TRAcP, and immunohi...
متن کاملPolyethylene Particles Induce Osteolysis in Calvaria of Wild-type Andimmunodeficient Mice
Introduction: Osteolysis around orthopaedic implants, a consequence of the wear process, is a major problem for the long-term survival of the implants. We and others previously reported quantitative versions of the murine calvarial model of titanium particle induced osteolysis [1,2]. However, the most common particle type that is generated from orthopaedic implants is ultrahigh molecular weight...
متن کاملIn Vivo Response to the Wear Debris of Low Temperature Degradation-free Zirconia/alumina Composites for the Bearing Surface of Total Hip Replacement
INTRODUCTION Ceramic femoral heads and liners have been developed to reduce the wear of conventional metal-on-UHMWPE bearing surface in the total hip replacement. Alumina and zirconia possessing excellent tribological properties have been used in clinical application. However, alumina has a risk of catastrophic failure due to a high brittleness, and zirconia has the low temperature degradation ...
متن کاملIn vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up
BACKGROUND Zirconia was introduced as an alternative to alumina for use in the femoral head. The yttria stabilized zirconia material was improved by adding alumina. We evaluated highly cross-linked polyethylene wear performance of zirconia in total hip arthroplasty. The hypothesis was that alumina stabilized zirconia could decrease highly cross-linked polyethylene wear. METHODS Highly cross-l...
متن کاملNew Surface Treatment to Reduce Alumina Coverage of Grit-blasted Implants
INTRODUCTION For more than 20 years alumina-blasted surfaces have been successfully used for cementless surgical implants, because of their good biocompatibility and rapid osseointegration. However, it has been shown recently that grit-blasting leads to partial embedding of aluminum oxide particles that can cover 24% to 40% of the surface, with a difference between manufacturers [1-2]. These pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomaterials
دوره 24 21 شماره
صفحات -
تاریخ انتشار 2003