Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations.
نویسندگان
چکیده
BACKGROUND Analogous to stenotic valve area in the assessment of valvular stenosis, regurgitant orifice area (ROA) represents a fundamental parameter to assess valvular insufficiency. However, this parameter has not been routinely available up to now. In this study, we introduce the concept and provide the methodology to calculate regurgitant orifice area noninvasively, based on the analysis of the proximal flow convergence zone. METHODS AND RESULTS In an in vitro study, we showed the feasibility and the accuracy of calculating effective ROA by the proximal flow convergence method throughout a range of driving pressures. The calculated and true ROA showed an excellent correlation with r = .992, delta ROA = -1.4 +/- 2.9 mm2. We then applied this concept clinically in 77 patients with mitral regurgitation and showed a very good correlation between effective ROA calculated by the proximal flow convergence method and calculated by the Doppler echocardiographic method: r = .95, delta ROA = -0.2 +/- 3.9 mm2. The ROA also correlated very well with Doppler echocardiographic-derived regurgitant stroke volume (r = .93) and regurgitant fraction (r = .82). In a subgroup of 20 patients who underwent invasive evaluation, the calculated effective ROA also correlated well with the angiographic grade of mitral regurgitation (rho = .81). CONCLUSIONS We conclude that effective ROA represents unique information on the severity of a regurgitant lesion and can easily be calculated by the proximal flow convergence method. This new parameter should enhance our understanding and improve the serial assessment of valvular regurgitation.
منابع مشابه
Automated flow rate calculations based on digital analysis of flow convergence proximal to regurgitant orifices.
OBJECTIVES The purpose of the study was to develop and validate an automated method for calculating regurgitant flow rate using color Doppler echocardiography. BACKGROUND The proximal flow convergence method is a promising approach to quantitate valvular regurgitation noninvasively because it allows one to calculate regurgitant flow rate and regurgitant orifice area; however, defining the loc...
متن کاملAssessment of Mitral Regurgitation Severity by Doppler Color Flow Mapping of the Vena Contracta in Dogs
BACKGROUND Although Doppler color flow mapping is widely used to assess the severity of mitral regurgitation (MR), a simple, accurate, and quantitative marker of MR by color flow mapping remains elusive. We hypothesized that vena contracta width by color flow mapping would accurately predict the severity of MR. METHODS AND RESULTS We studied 80 patients with MR. Vena contracta width was measu...
متن کاملA new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice. An in vitro study.
While color Doppler flow mapping has yielded a quick and relatively sensitive method for visualizing the turbulent jets generated in valvular insufficiency, quantification of the degree of valvular insufficiency has been limited by the dependence of visualization of turbulent jets on hemodynamic as well as instrument-related factors. Color Doppler flow imaging, however, does have the capability...
متن کاملCurrent status of flow convergence for clinical applications: is it a leaning tower of "PISA"?
Spatial appreciation of flow velocities using Doppler color flow mapping has led to quantitative evaluation of the zone of flow convergence proximal to a regurgitant orifice. Based on the theory of conservation of mass, geometric analysis, assuming a series of hemispheric shells of increasing velocity as flow converges on the orifice--the so-called proximal isovelocity surface area (PISA) effec...
متن کاملQuantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.
BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 88 3 شماره
صفحات -
تاریخ انتشار 1993