Effect of upper strap downward displacement on n95 filtering facepiece respirator fit factors: a pilot study.
نویسندگان
چکیده
Fifteen subjects underwent three replicates of quantitative respirator fit-testing with N95 filtering facepiece respirators that were donned with the upper strap high on the occiput, as per the manufacturers' donning instructions. Each fit-test was immediately followed by repeat fit-testing with the upper strap downwardly displaced to the level of the ear sulcus to determine any change in fit factors that might occur with upper strap downward slippage. A total of 35/45 (78%) initial fit-tests had a passing score (fit factor ≥ 100) with the top strap high on the occiput and 33/35 (94%) of these passed subsequent fit-testing after the top strap was displaced downward to the ear sulcus. Geometric mean fit factors for the initial passed fit-tests, and following downward strap displacement, were 217 ± 1.6 and 207 ± 1.9, respectively (p = 0.64). Downward displacement of the top strap did not significantly impact fit factors of N95 FFRs that had previously passed fit-testing.
منابع مشابه
Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.
A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...
متن کاملFitting Characteristics of N95 Filtering-Facepiece Respirators Used Widely in China
BACKGROUND Millions of people rely on N95 filtering facepiece respirators to reduce the risk of airborne particles and prevent them from respiratory infections. However, there are no respirator fit testing and training regulations in China. Meanwhile, no study has been conducted to investigate the fit of various respirators. The objective of this study was to investigate whether people obtained...
متن کاملHeadform and N95 filtering facepiece respirator interaction: contact pressure simulation and validation.
This article presents a computational and experimental study of contact pressure between six N95 filtering facepiece respirators (FFRs) and five newly developed digital headforms (small, medium, large, long/narrow, and short/wide). Contact interaction is simulated using the finite element method and validated by experiments using a pressure mapping system. The headform model has multiple layers...
متن کاملEffect of surgical masks worn concurrently over N95 filtering facepiece respirators: extended service life versus increased user burden.
Growing concern over the availability of Respiratory protective devices (eg, filtering facepiece Respirators), in the face of the probable extreme demand brought on by a pandemic influenza, has prompted the suggestion that useful life of N95 filtering facepiece Respirator can be extended by the concurrent use of a surgical mask as an outer protective barrier over the Respirator. Personal protec...
متن کاملRespiratory protection provided by N95 filtering facepiece respirators against airborne dust and microorganisms in agricultural farms.
A new system was used to determine the workplace protection factors (WPF) for dust and bioaerosols in agricultural environments. The field study was performed with a subject wearing an N95 filtering facepiece respirator while performing animal feeding, grain harvesting and unloading, and routine investigation of facilities. As expected, the geometric means (GM) of the WPFs increased with increa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of occupational and environmental hygiene
دوره 11 5 شماره
صفحات -
تاریخ انتشار 2014