Randomized comparison of everolimus-eluting stents and sirolimus-eluting stents in patients with ST elevation myocardial infarction: RACES-MI trial.
نویسندگان
چکیده
OBJECTIVES The aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty. BACKGROUND Drug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI. METHODS Consecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up. RESULTS From April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035). CONCLUSIONS This study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982).
منابع مشابه
Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...
متن کاملTwo-Year Results of an Open-Label Randomized Comparison of Everolimus-Eluting Stents and Sirolimus-Eluting Stents
BACKGROUND Second generation drug-eluting stents were developed to improve the safety and efficacy of first generation stents. So far, limited long term randomized data exist comparing the second generation everolimus-eluting stents (EES) with first generation sirolimus-eluting stents (SES). METHODS A prospective, open-label, randomized, single center trial comparing EES and SES in all-comer ...
متن کاملEverolimus- and sirolimus-eluting stents in patients with and without ST-segment elevation myocardial infarction
AIMS Everolimus-eluting stents (EES) were superior to sirolimus-eluting stents (SES) in a dedicated myocardial infarction trial, a finding that was not observed in trials with low percentages of ST-elevation myocardial infarction (STEMI). Therefore, this study sought to investigate the influence of clinical presentation on outcome after EES and SES implantation. METHODS A pooled population of...
متن کاملInterventional Cardiology Randomized Comparison of Everolimus-Eluting Stent Versus Sirolimus-Eluting Stent Implantation for De Novo Coronary Artery Disease in Patients With Diabetes Mellitus (ESSENCE-DIABETES) Results From the ESSENCE-DIABETES Trial
Background—Drug-eluting stents significantly improved angiographic and clinical outcomes compared with bare metal stents in diabetic patients. However, a comparison of everolimus-eluting stents and sirolimus-eluting stents in diabetic patients has not been evaluated. Therefore we compared effectiveness of everolimus-eluting stents and sirolimus-eluting stents in patients with diabetes mellitus....
متن کاملClinical outcomes with drug-eluting and bare-metal stents in patients with ST-segment elevation myocardial infarction: evidence from a comprehensive network meta-analysis.
OBJECTIVES The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis. BACKGROUND The relative safety of DES and BMS in patients with STEMI continues to be debated, and whether advances have been made in this regard with second-gen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 7 8 شماره
صفحات -
تاریخ انتشار 2014