Nonuniform absorbed dose distribution in the kidney: the influence of organ architecture.

نویسندگان

  • Alan Green
  • Aiden Flynn
  • R Barbara Pedley
  • Jason Dearling
  • Richard Begent
چکیده

The development of novel, systemically administered radionuclide therapies (such as radioimmunotherapy) relies on the ability to predict dose-limiting toxicity to normal tissue. Where the kidney is the principal route of excretion of the radionuclide preparation and/or breakdown of products, nephrotoxicity may be the dose-limiting factor. Until recently, conventional (MIRD) dosimetry assumed the distribution in the kidney to be uniform. A new MIRD phantom of the kidney models it as a set of uniform suborgans. In the work described here, the assumption of uniformity of distribution and of heterogeneity of dose rate (and, thus, absorbed dose) was tested in the mouse model. In this paper, we examine the nonuniformity of distribution and the subsequent dose rate for 4 antibody preparations (IgG (150 kD), F(ab)'(2) (100 kD), Fab (50 kD) and sFv (27 kD)) labeled with 4 radionuclides ((125)I, (131)I, (186)Re, and (90)Y) of interest in radioimmunotherapy (RIT). The kidney was considered as a whole and as two suborgans (cortex and medulla), and the nonuniformity of the dose-rate distribution was measured by a correlation of modeled dose-rate distribution with the dose-rate distribution obtained for an equivalent uniform radionuclide distribution. The heterogeneity of distribution, the inter- and intra-suborgan, was seen to increase as the molecular weight of the antibodies decreased. The assumption of uniform activity distribution for the whole kidney gives a poor estimation of the distribution of the dose rate. In the cortex, the longer-range emitters smooth out the effect of heterogeneous distribution and, in mice, an assumption of uniform cortex self-dose distribution may be sufficient for simple calculations. It is unclear how much this smoothing would be relevant in the human kidney.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Organ dose in kidney imaging with contrast media

Introduction:Intravenous urography (IVU) test includes high number of images and extended imaging size. These make IVU as a diagnostic method with high absorbed doses by sensitive organs such as intestine and gonads in pelvic-abdominal area. In this study absorbed doses of pelvic-abdomen sensitive organs such as Adrenal, Bladder, Colon and Gonads in IVU test. <stron...

متن کامل

A Microdosimetry model of kidney for nephrotoxicity due to internal radiation therapy

Introduction: We describe a nephron-based dosimetry model for renal toxicity for radiopharmaceutical therapy suited to the nonuniform activity distribution of radiopharmaceutical. In radiopharmaceutical therapy, renal toxicity is observed while whole-kidney and renal cortex absorbed dose values are below toxicity thresholds established by external beam and targeted radiope ptid...

متن کامل

اندازه‌گیری دوز جذبی کلیه‌ها، کبد، مثانه و تخمدان در آزمایش سنتی گرافی کلیه با رادیو داروهای 99mTc-EC و 99mTc-DTPA با استفاده از فنتوم به روش دوزیمتری ترمولومینسانس

    Background: In this survey the absorbed dose by kidneys, bladder, liver and ovaries with 99mTc-EC (99mTc Ethylene dicysteine) renal scintigraphy was measured and compared with the absorbed dose from 99mTc-DTPA (99mTc - Dietheylne Triamine Penta-Acid), which often is used in renal scintigraphy.Methods: In this applicable study, we used a water phantom with geometrical sizes similar to that o...

متن کامل

Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...

متن کامل

Determination of internal absorbed dose from radiation of 111In-Rituximab in body

Introduction: There are many ways to treat cancer and pain relief. One of the methods is radiopharmaceutical therapy. Indium 111-rituximab contains the radioisotope indium-111 and rituximab. The Indium-111, after decay, emits gamma rays with energies of 245 KeV and 171 KeV, and beta-radiation of 26 KeV. In this study, the absorbed dose of 111In-Rituximab in human body was calcu...

متن کامل

A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer biotherapy & radiopharmaceuticals

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2004