Matrix effects and the performance and selection of quality-control procedures to monitor PO2 measurements.
نویسندگان
چکیده
We have assessed how variation in the matrix of control materials would affect error detection and false-rejection characteristics of quality-control (QC) procedures used to monitor PO2 in blood gas measurements. To determine the expected QC performance, we generated power curves for S(mat)/S(meas) ratios of 0.0-4.0. These curves were used to estimate the probabilities of rejecting analytical runs having medically important errors, calculated from the quality required by the CLIA '88 proficiency testing criterion and the precision and accuracy expected for a typical analytical system. When S(mat)/S(meas) ratios are low, the effects of matrix on QC performance are not serious, permitting selections of QC procedures based on simple power curves for a single component of variation. As S(mat)/S(meas) ratios increase, single-rule procedures generally show a loss in error detection, whereas multirule procedures, including the 3(1)s control rule, show an increase in false rejections. An optimized QC design is presented.
منابع مشابه
Effects of Rosemary (Rosmarinus officinalis) Extract on Performance, Antioxidant Ability and Blood Gas Indices of Broiler Chickens Treated with Sodium Nitrate in Drinking Water
A total of 220 broiler chicks in five groups were used to reveal the effects of different levels of 0.0, 1.5, 3.0 and 6.0 mL/L rosemary extract along with sodium nitrate (27.4 mg/L) in drinking water as compared to the control (without any supplement in water) on performance and antioxidant potential of treated broiler chickens. Body weight gain and feed conversion ratio were negatively affecte...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملWhy Should We Have a Periodic Safety and Performance Program for Medical Devices
Nowadays, more than 10,000 different types of medical devices can be found in hospitals.These devices used in medical centers and hospitals for monitoring and treatment of patients require periodic safety and performance checking in order to have confidence in their functioning and operation. Physicians need better accurate medical measurements in order to better diagnose diseases, monitor pati...
متن کاملSuppliers Selection in Consideration of Risks by a Neural Network
Faced with the dynamic demands of a changing market, companies are facing fierce competition, which forces them to consider more and more new approaches to improve quality, reduce costs, produce on time, control their risks and remain successful in the face of any disruption. It is clear that the choice of appropriate suppliers is one of the key factors in increasing the competitiveness of comp...
متن کاملIntroducing Triangular Fuzzy Process Capability Indices to Evaluate Performance of Continuous Production Process
Process capability indices (PCIs) can be used as an effective tool for measuring product quality and process performance. In classic quality control there are some limitations which prevent a deep and flexible analysis because of the crisp definition of PCA‟s parameters. Fuzzy set theory can be used to add more flexibility to process capability analyses. In this study, the fuzzy X ba and MRx ba...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 3 شماره
صفحات -
تاریخ انتشار 1996