Comparison of Swedish interactive threshold algorithm and full threshold algorithm for glaucomatous visual field loss.

نویسندگان

  • Y Aoki
  • G Takahashi
  • K Kitahara
چکیده

PURPOSE To compare the prevalence of visual field loss, the sensitivity distribution, and the size and depth of glaucomatous visual field defects using the standard full threshold (FT) and the Swedish interactive threshold algorithm (SITA) standard (SS) procedures in patients with early or suspected glaucoma. METHODS Automated perimetry findings were retrospectively evaluated in 53 patients (105 eyes) with early or suspected glaucoma. RESULTS The number of eyes judged to have glaucomatous visual field loss by SS (48 eyes) was significantly larger than what was found with FT (35 eyes), and 70 eyes were classified as pre-perimetric glaucoma. In these 70 eyes, there were many locations where the sensitivity was significantly higher with SS than with FT (intrasubject difference), and SS had less intersubject variability than FT at most locations. The cumulative decibel scores at the region of glaucomatous defects were larger with SS (206.2+/-103.3 dB) than with FT (162.1+/-87.5 dB) (p=0.02), which indicated that the depth of defects measured by SS was shallower than that by FT. The sizes of defects were significantly larger with SS (11.2+/-5.6) than with FT (9.7+/-5.1) (p<0.05). CONCLUSIONS Glaucomatous defects were measured as being significantly shallower and larger with SS than with FT. In addition, the prevalence of visual field defect was higher with SS according to some of the criteria for glaucomatous visual field defects. These results might be related to the fact that SS strategy has a lower variability and to the Bayesian statistical properties of the SITA algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does the Swedish Interactive Threshold Algorithm (SITA) accurately map visual field loss attributed to vigabatrin?

BACKGROUND Vigabatrin (VGB) is an anti-epileptic medication which has been linked to peripheral constriction of the visual field. Documenting the natural history associated with continued VGB exposure is important when making decisions about the risk and benefits associated with the treatment. Due to its speed the Swedish Interactive Threshold Algorithm (SITA) has become the algorithm of choice...

متن کامل

Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms.

OBJECTIVES To compare the severity, size, and depth of glaucomatous visual field defects using standard full threshold (FT), Swedish interactive threshold algorithm (SITA) standard (SS), and SITA fast (SF) algorithms of the Humphrey perimeter. METHODS A prospective observational case series of 77 patients with glaucoma performed FT, SS, and SF 30-2 white-on-white testing programs on the same ...

متن کامل

A new rapid threshold algorithm for short-wavelength automated perimetry.

PURPOSE To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP). METHODS Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selec...

متن کامل

Properties of perimetric threshold estimates from full threshold, ZEST, and SITA-like strategies, as determined by computer simulation.

PURPOSE To investigate the accuracy and precision of threshold estimates returned by two Bayesian perimetric strategies, staircase-QUEST or SQ (a Swedish interactive threshold algorithm [SITA]-like strategy) and ZEST (zippy estimation by sequential testing), and to compare these measures with those of the full-threshold (FT) algorithm. METHODS A computerized visual field simulation model was ...

متن کامل

Comparison of Different Analytic Algorithms for Interpretation of the Swedish Interactive Threshold Algorithm Strategy

OBJECTIVE To compare 4 analytic algorithms for interpretation of the Swedish Interactive Threshold Algorithm. INTRODUCTION Analytic algorithms were initially developed for interpretation of standard automated perimetry (using a full threshold strategy). The Swedish interactive threshold algorithm is a novel strategy that was developed to shorten test duration. METHODS One hundred forty-thre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2007