Particle Based Visualization of Stress Distribution Caused by the Aortic Valve Deformation
نویسندگان
چکیده
Medical and engineering technologies have developed the surgical simulators, which allow users to train for surgical skills. To perform the aortic valve replacement, which is one of the cardiovascular surgeries, it is necessary to examine not only the timing of the heart pulsating but also the stress distribution on the aortic valve. For pre-operative planning, we have visualized the stress on the aortic valve due to the deformation of the aorta and blood stream. In our research, simulations of the deformation of the aortic valve and blood stream have been performed with 3D aorta and aortic valve models, which are composed of particles. In the simulation, the aortic valve and blood models are treated as an elastic body and Hershel-Bulkley fluid, respectively. We have used MPS (Moving Particle Semi-implicit) as the particle method; however, it is known that MPS method cannot specify the stress because the pressure among the particles on the free surfaces is zero. Then, in this paper, we propose more stable pressure calculation by considering virtual particles. As a result, visualization of the stress distribution on the aortic valve has been achieved.
منابع مشابه
Comparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملFailure analysis of an intake valve in a gasoline engine
This paper presents a failure analysis on a failed intake valve in a gasoline engine. During an endurance test, an intake valve was broken and caused some damages on the piston. Material examinations (by a light microscope and also a scanning electron microscope) were conducted on the fracture surface of the intake valve shaft. Results showed that no pores or defects could be observed and the m...
متن کاملMicrostructural Evolution of X45CrNiW189 Valve Steel During Hot Deformation
The hot compression tests were carried on X45CrNiW189 valve steel (X45) in the temperature range of 1000– 1200 °C and the strain rate range of 0.004 – 0.5 s-1 in order to study the high temperature softening behavior of this steel. For the exact prediction of flow stress, the effective stress-effective strain curves were obtained from experiments under various conditions. On the basis of experi...
متن کاملSimulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.
The asymmetric, elliptical shape of a transcatheter aortic valve (TAV), after implantation into a calcified aortic root, has been clinically observed. However, the impact of elliptical TAV configuration on TAV leaflet stress and strain distribution and valve regurgitation is largely unknown. In this study, we developed computational models of elliptical TAVs based on a thin pericardial bioprost...
متن کاملApplications of higher order shear deformation theories on stress distribution in a five layer sandwich plate
In this paper, layerwise theory (LT) along with the first, second and third-order shear deformation theories (FSDT, SSDT and TSDT) are used to determine the stress distribution in a simply supported square sandwich plate subjected to a uniformly distributed load. Two functionally graded (FG) face sheets encapsulate an elastomeric core while two epoxy adhesive layers adhere the core to the face ...
متن کامل