Exposure Buildup Factors for Heavy Metal Oxide Glass: A Radiation Shield
نویسندگان
چکیده
منابع مشابه
محاسبه ی ضرایب انباشت چشمه ی گاما با طیف انرژی پیوسته برای آب، آهن و سرب به وسیله ی کد مونت کارلو
The exposure buildup factors are important for determining the shield thickness of gamma and X-ray. Without taking this factor into account, the estimated thickness of the shield is less than what is expected which leads to an excessive received radiation exposure of staffs or patients. Given that the exposure buildup factor for the monoenergetic homogenous point sources have been calculated by...
متن کاملA STUDY OF GAMMA RAY EXPOSURE BUILDUP FACTORS IN STRATIFIED SHIELDS FOR POINT ISOTROPIC SOURCES, INCLUDING THE EFFECTS OF INCOHERENT AND COHERENT SCATTERING
The effects of including incoherent (bound-electron) and coherent (Rayleigh) scattering in exposure buildup factor calculations for point isotropic gamma ray sources, penetrating a two-layer water-lead shield have been investigated in the gamma ray energy (E?) range of 40 keV to 3 MeV. Incoherent scattering decreases the values of these factors in both layers up to E? ~ 200 keV and the effect i...
متن کامل“Study of stable gallium oxide heavey metal Ga2O3-Bi2O3-PbO system glasses proposed as a base for optically noble glazes and enamels”
Ultra optical glasses are proposed for attaining noble glazes of high reflection and shine. In addition, these glasses can be used as semi-mirrors and optical instruments. In this reseach attempts were devoted mainly to introduce a glass system with the highest possible refractive index in which the highest reflection is desirable. Thus different amounts of heavy metal oxides modifiers, such as...
متن کاملDetermination of Photon Ambient Dose Buildup Factors for Radiological Applications for Points and Plaque Source Configurations Using MCNP5
Photon ambient dose equivalent buildup factors were calculated for point and plaque isotropic cobalt-60 and cesium-137 radioactive sources irradiating a finite slab shield materials of ordinary concrete, barite concrete, lead, lead glass and water using MCNP5 code. Studied shield thickness ranged from 1 to 15 mean free paths (mfp). A variance reduction technique available in the code was used t...
متن کاملEffect of Material and Wall Thickness Buildup Caps on the Head ScatterFactor Measurements in Irregular Fields Shielded by Cerrobend
Introduction: The head scatter factor (Sc) is important to measurements radiation beam and beam modeling of treatment planning systems used for advanced radiation therapy techniques. This study aimed to investigate the design of a mini-phantom to measurement variations in collimator Sc in the presence of shielding blocks for shaping the beam using different field sizes. <str...
متن کامل