Effect of decentration on the optical performance in multifocal intraocular lenses.

نویسندگان

  • Mitsutaka Soda
  • Shigeo Yaguchi
چکیده

AIMS To evaluate the influence of decentration on optical performance in multifocal intraocular lenses (IOLs) using eye models. METHODS This study evaluated 4 types of multifocal IOLs (ReSTOR SA60D3, Alcon; TECNIS Multifocal ZM900, AMO; ReZoom, AMO; SFX-MV1, Hoya). The evaluations were based on measurements of the near and far modulation transfer function (MTF) and visualized actual near images (newspaper) using eye models with the IOL horizontally displaced 0, 0.25, 0.5, 0.75 and 1.0 mm from the center. RESULTS For the diffractive ReSTOR the near MTF decreased with increasing decentration. The near images (newspaper characters) became difficult to distinguish at a decentration of 1.0 mm. For the diffractive ZM900, the near and far MTFs gradually decreased with increasing decentration. For the refractive ReZoom and SFX-MV1, we observed almost no change in the near MTF from a decentration of 0-1.0 mm. However, the far MTF clearly decreased starting at a decentration of 1.0 mm for ReZoom and 0.75 mm for SFX-MV1. CONCLUSION The MTFs and near images are affected to a different extent depending on the design of multifocal IOLs; clinically relevant effects are not to be expected up to a decentration of 0.75 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار

Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...

متن کامل

Laboratory Evaluation of the Influence of Decentration and Pupil Size on the Optical Performance of a Monofocal, Bifocal, and Trifocal Intraocular Lens.

PURPOSE To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing. METHODS Using an optical bench set-up, an aspheric monofocal (CT ASPHINA 409M; Carl Zeiss Meditec, Jena, Germany), an aspheric diffractive bifocal (AT LISA 809M; Carl Ze...

متن کامل

Analysis of the power profile of a new soft contact lens for myopia progression

1. Wagner S, Conrad F, Bakaraju RC, Fedtke C, Ehrmann K, Holden BA. Power profiles of single vision and multifocal soft contact lenses. Cont Lens Anterior Eye. 2014;38:2--14. 2. Plainis S, Atchison DA, Charman WN. Power profiles of multifocal contact lenses and their interpretation. Optom Vis Sci. 2013;90:1066--1077. 3. Joannes L, Hough T, Hutsebaut X, et al. The reproducibility of a new power ...

متن کامل

Through focus image quality of eyes implanted with monofocal and multifocal intraocular lenses

Intraocular lenses (lOLs) are commonly implanted in cataract surgery. Initially lOLs were mainly monofocal, but at present there are many multifocal lOLs available, which are being implanted. Multifocal lOLs have the potential advantage of reducing the dependence on spectacle correction for near vision after cataract surgery. Because the multifocal lOLs superimpose the near and far images on th...

متن کامل

Optical performance of monofocal versus multifocal intraocular lenses.

In their recent paper, Ortiz et al. studied the optical performance of monofocal and multifocal intraocular lenses (IOLs) in the human eye. Their main conclusion was that of the IOLs studied, the hybrid refractive–diffractive IOLwas the least affected by pupil diameter in terms of intraocular aberrations. This IOL type also showed a smaller increase in optical aberrations during pupil dilation....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde

دوره 227 4  شماره 

صفحات  -

تاریخ انتشار 2012