Environmental payback time analysis of a roof-mounted building-integrated photovoltaic (BIPV) system in Hong Kong

نویسندگان

  • L. Lu
  • H. X. Yang
چکیده

0306-2619/$ see front matter 2010 Elsevier Ltd. A doi:10.1016/j.apenergy.2010.06.011 * Corresponding author. Tel.: +852 3400 3596; fax: E-mail address: [email protected] (L. Lu). This paper reports the investigation results of the energy payback time (EPBT) and greenhouse-gas payback time (GPBT) of a rooftop BIPV system (grid-connected) in Hong Kong to measure its sustainability. The 22 kWp PV array is facing south with inclined angle of 22.5 . The hourly solar irradiance and ambient air temperature from 1996 to 2000 were used as weather data input. The annual power output was found to be 28,154 kWh. The embodied energy for the whole system in the lifespan was 205,816 kWh, including 71% from PV modules and 29% from balance of system (BOS). The percentage of embodied energy for silicon purification and processing reached 46%. The EPBT of the PV system was 7.3 years, and the GPBT was estimated to be 5.2 years considering fuel mixture composition of local power stations. This paper also discussed the EPBTs for different orientations, ranging from 7.1 years (optimal orientation) to 20.0 years (west-facing vertical PV façade). The results show that the ‘sustainability’ of a PV system is affected by its installation orientation and location. Choosing locations and orientations with higher incident solar irradiance is one key for the sustainability of BIPV technology applications. 2010 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can Pv or Solar Thermal Systems Be Cost Effective Ways of Reducing Co2 Emissions for Residential Buildings?

This paper compares two solar systems, an actual building integrated, photovoltaic roof (BIPV) and a notional solar thermal system for a residential block in London, UK. The carbon payback for the solar thermal system is 2 years, the BIPV system has a carbon payback of 6 years. Simple economic payback times for both systems are more than 50 years. Calculations considering the current UK energy ...

متن کامل

Defining the Building-Integrated Photovoltaic Designs in architecture and urbanism with Emphasis on Usage in Iran

Demand of energy is more sensible now because of population growth and economic growth of countries. In order to increase of energy consumption around the world and environment pollution, attention to the renewable energy such as solar energy is inevitable. Building-integrated photovoltaic (BIPV) electric power systems not only produce electricity, they are also part of the building. For exam...

متن کامل

Economics of Building Integrated PV In China

This paper presents a technical and economic analysis of building-integrated photovoltaic (BIPV) applications for commercial buildings in Shanghai and Beijing China. The analysis assumes that the array area is 105 m (equivalent to 6.3 kWp for amorphous silicon thin film technology and 10.0 kWp for polycrystalline technology). Rooftop and curtain wall applications are considered. BIPV is analyze...

متن کامل

Building Integrated Photovoltaic is a Cost Effective and Environmental Friendly Solution

Building integrated photovoltaic (BIPV) market is under developing stage with a relatively low number of installations worldwide. However, integrating photovoltaic technology into buildings is straight forward as no additional space is required and building materials are simply replaced by PV modules. Although BIPV is considered a promising technology, especially where land for large-scale PV p...

متن کامل

Quantification of Thermal Energy Performance Improvement for Building Integrated Photovoltaic Double-Skin Façade Using Analytical Method

In this research, an analytical method for quantification of the thermal energy performance improvement for a building integrated photovoltaic double-skin façade has provided. The system has been suggested as a retrofit measure for an existing building in Tehran. The effect of thermal performance has been analyzed through computer-assisted developed code using engineering equation solver softwa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010