I-labelled radioligands. A comparison between different imaging systems and data acquisition protocols using Monte Carlo simulation

نویسندگان

  • Cristina Crespo
  • Judith Gallego
  • Albert Cot
  • Carles Falcón
  • Pablo Aguiar
  • Josep Sempau
  • Francisco Lomeña
  • Francisco Calviño
  • Javier Pavía
  • Domènec Ros
چکیده

Purpose I-labelled radioligands are commonly used for single-photon emission computed tomography (SPECT) imaging of the dopaminergic system to study the dopamine transporter binding. The aim of this work was to compare the quantitative capabilities of two different SPECT systems through Monte Carlo (MC) simulation. Methods The SimSET MC code was employed to generate simulated projections of a numerical phantom for two gamma cameras equipped with a parallel and a fan-beam collimator, respectively. A fully 3D iterative reconstruction algorithm was used to compensate for attenuation, the spatially variant point spread function (PSF) and scatter. A post-reconstruction partial volume effect (PVE) compensation was also developed. Results For both systems, the correction for all degradations and PVE compensation resulted in recovery factors of the theoretical specific uptake ratio (SUR) close to 100%. For a SUR value of 4, the recovered SUR for the parallel imaging system was 33% for a reconstruction without corrections (OSEM), 45% for a reconstruction with attenuation correction (OSEM-A), 56% for a 3D reconstruction with attenuation and PSF corrections (OSEM-AP), 68% for OSEM-AP with scatter correction (OSEM-APS) and 97% for OSEM-APS plus PVE compensation (OSEM-APSV). For the fan-beam imaging system, the recovered SUR was 41% without Eur J Nucl Med Mol Imaging (2008) 35:1334–1342 DOI 10.1007/s00259-007-0711-z C. Crespo :A. Cot :C. Falcón : P. Aguiar :D. Ros (*) Unitat de Biofísica i Bioenginyeria, Departament de Ciències Fisiològiques I, Facultat de Medicina, Universitat de Barcelona—IDIBAPS, Casanova 143, 08036 Barcelona, Spain e-mail: [email protected] J. Gallego : J. Sempau : F. Calviño Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya, Barcelona, Spain J. Gallego Institut de Bioenginyeria de Catalunya, Barcelona, Spain A. Cot : F. Calviño Secció d’Enginyeria Nuclear, Departament de Física i Enginyeria Nuclear, Universitat Politècnica de Catalunya, Barcelona, Spain C. Falcón :D. Pareto : J. Sempau : J. Pavía :D. Ros CIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona, Spain S. Bullich Center for Imaging in Psychiatry, CRC-MAR, Hospital del Mar, Barcelona, Spain D. Pareto Institut d’Alta Tecnologia, PRBB, Barcelona, Spain F. Lomeña : J. Pavía Servei de Medicina Nuclear, Hospital Clínic, IDIBAPS, Barcelona, Spain corrections, 55% for OSEM-A, 65% for OSEM-AP, 75% for OSEM-APS and 102% for OSEM-APSV. Conclusion Our findings indicate that the correction for degradations increases the quantification accuracy, with PVE compensation playing a major role in the SUR quantification. The proposed methodology allows us to reach similar SUR values for different SPECT systems, thereby allowing a reliable standardisation in multicentric studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

A Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

متن کامل

The comparison between 6 MV Primus LINAC simulation output using EGSnrc and commissioning data

Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...

متن کامل

Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging

Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...

متن کامل

Kinetic Monte Carlo Study of Biodiesel Production through Transesterification of Brassica Carinata Oil

In the present study, the kinetics of biodiesel production through transesterification of Brassica carinata oil with methanol in the presence of Potassium Hydroxide is investigated by kinetic Monte Carlo simulation. The obtained results from simulation agree qualitatively with the existing experimental data. The kinetics data for each step of suggested mechanism are confirmed by simulation. By ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008