Reproducible extracellular vesicle size and concentration determination with tunable resistive pulse sensing

نویسندگان

  • Frank A. W. Coumans
  • Edwin van der Pol
  • Anita N. Böing
  • Najat Hajji
  • Guus Sturk
  • Ton G. van Leeuwen
  • Rienk Nieuwland
چکیده

INTRODUCTION The size of extracellular vesicles (EVs) can be determined with a tunable resistive pulse sensor (TRPS). Because the sensing pore diameter varies from pore to pore, the minimum detectable diameter also varies. The aim of this study is to determine and improve the reproducibility of TRPS measurements. METHODS Experiments were performed with the qNano system (Izon) using beads and a standard urine vesicle sample. With a combination of voltage and stretch that yields a high blockade height, we investigate whether the minimum detected diameter is more reproducible when we configure the instrument targeting (a) fixed stretch and voltage, or (b) fixed blockade height. RESULTS Daily measurements with a fixed stretch and voltage (n=102) on a standard urine sample show a minimum detected vesicle diameter of 128±19 nm [mean±standard deviation; coefficient of variation (CV) 14.8%]. The vesicle concentration was 2.4·109±3.8·109 vesicles/mL (range 1.4·108-1.8·1010). When we compared setting a fixed stretch and voltage to setting a fixed blockade height on 3 different pores, we found a minimum detected vesicle diameter of 118 nm (CV 15.5%, stretch), and 123 nm (CV 4.5%, blockade height). The detected vesicle concentration was 3.2-8.2·108 vesicles/mL with fixed stretch and 6.4-7.8·108 vesicles/mL with fixed blockade height. Summary/conclusion: Pore-to-pore variability is the cause of the variation in minimum detected size when setting a fixed stretch and voltage. The reproducibility of the minimum detectable diameter is much improved by setting a fixed blockade height.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tunable Resistive Pulse Sensing for the Characterization of Extracellular Vesicles.

Accurate characterization of extracellular vesicles (EVs), including exosomes and microvesicles, is essential to obtain further knowledge on the biological relevance of EVs. Tunable resistive pulse sensing (tRPS) has shown promise as a method for single particle-based quantification and size profiling of EVs. Here, we describe the technical background of tRPS and its applications for EV charact...

متن کامل

Quantification and Size-profiling of Extracellular Vesicles Using Tunable Resistive Pulse Sensing

Extracellular vesicles (EVs), including 'microvesicles' and 'exosomes', are highly abundant in bodily fluids. Recent years have witnessed a tremendous increase in interest in EVs. EVs have been shown to play important roles in various physiological and pathological processes, including coagulation, immune responses, and cancer. In addition, EVs have potential as therapeutic agents, for instance...

متن کامل

Integrated Method for Purification and Single-Particle Characterization of Lentiviral Vector Systems by Size Exclusion Chromatography and Tunable Resistive Pulse Sensing

Elements derived from lentiviral particles such as viral vectors or virus-like particles are commonly used for biotechnological and biomedical applications, for example in mammalian protein expression, gene delivery or therapy, and vaccine development. Preparations of high purity are necessary in most cases, especially for clinical applications. For purification, a wide range of methods are ava...

متن کامل

Differential detergent sensitivity of extracellular vesicle subpopulations.

Extracellular vesicles (including exosomes, microvesicles and apoptotic bodies) are currently attracting rapidly increasing attention from various fields of biology due to their ability to carry complex information and act as autocrine, paracrine and even endocrine intercellular messengers. In the present study we investigated the sensitivity of size-based subpopulations of extracellular vesicl...

متن کامل

Applications of tunable resistive pulse sensing.

Tunable resistive pulse sensing (TRPS) is an experimental technique that has been used to study and characterise colloidal particles ranging from approximately 50 nm in diameter up to the size of cells. The primary aim of this Review is to provide a guide to the characteristics and roles of TRPS in recent applied research. Relevant studies reflect both the maturation of the technique and the gr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014