We read with interest the paper by Rahman about compliance temperature monitors for scoliosis braces [1]. This study confirms our everyday clinical experience with compliance monitors for braced patients. In fact, since 2010, our institute has systematically applied this kind of monitoring in everyday clinical practice [2]. We already have 2,106 patients in brace treatment who allowed us to monitor them during therapy. Thanks to this large experience, we now know that the use of this tool can improve results for our patients. Today, when braced patients do not accept the use of sensors, treatment becomes more difficult and less accurate. Recently, we interviewed patients and parents who said they would recommend the use of these monitors to other families (unpublished data). The awareness of being monitored, if well managed by explaining to patients and parents its advantages, can increase compliance, as shown in a randomized clinical trial by Miller et al. [3]. We must also report that our results completely differ from those previously published, since the compliance we documented was dramatically higher than what is usually reported (91.7 % of prescription; IC95 56.6–101.7 %), with 60 % of patients wearing the brace as much or even more than required [2]. These results are also maintained in the long term [4], which is probably a result of team management [5] during treatment according to the current SOSORT guidelines [6], and of the application of an externally symmetric and patient-oriented brace (SPoRT Brace) [7]. In addition, we encourage patients to maintain their normal everyday activities, including sports [8–10]. Even though the reliability of compliance through temperature monitors has been demonstrated [11–13], some authors advocate that these devices cannot measure the quality of brace wear; therefore, patients can reach the ‘on’ temperature without wearing the brace at the correct tightness [14]. This could be true in some cases, even if, in our experience, a correct set up of the temperature thresholds could reduce this kind of error. It would have been interesting to know the point of view of the authors and their own experience with the Cricket sensor. In the current study, the authors reported some concerns related to the variability of brace prescriptions in the sample included in their study. Previous studies did not find a correlation between compliance and dosage, even though most clinicians would expect the highest compliance in night-time brace wear, as it can be considered the easiest dosage. On the contrary, we previously found that the number of hours of brace wearing prescribed (HBW) might positively affect compliance. In our cohort, patients with 23 HBW were more compliant than were those with 18 HBW [2]. This may be justified by the severity of the curve, which may scare patients and motivate them to be adherent, or the simplicity of the prescription. A 1-h break per day is easy to understand and manage as patients must do everything while wearing their brace. The sample considered in our study included only patients with a fulltime brace wear prescription (18–23 h per day). The & Sabrina Donzelli [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adolescents with idiopathic scoliosis and their parents have a positive attitude towards the Thermobrace monitor: results from a survey

BACKGROUND A temperature monitor is used to objectively measure brace wear time in adolescent idiopathic scoliosis. The reliability of this device have been demonstrated, and some specialists introduced the use of a compliance monitor as a standard of care in everyday clinical practice, as we did since 2010 with the Thermobrace (TB). The attitude towards these objective monitors has never been ...

متن کامل

Electronic monitoring of orthopedic brace compliance

PURPOSE Brace compliance measurement in adolescent idiopathic scoliosis (AIS) has been the subject of a few recent studies. Various sensors have been developed to measure compliance. We have developed a temperature-based data logger-the Cricket-specifically for scoliosis braces, with associated custom software, that is embedded directly in the brace. The purpose of this study was to analyze pat...

متن کامل

It is possible to make patients use braces the hours prescribed: first results from the thermobrace clinical everyday usage

Materials and methods Population: 68 scoliosis consecutive patients (79% females, age 14.2±2.4) who accepted to use Thermobrace and had finished at least one period of treatment on the 31st December 2010 [1,2]. Actual hours worn per day were measured; compliance (percentage of prescription) and reported compliance (percentage of hours reported by the patient) were calculated. For reliability pu...

متن کامل

The BrAIST study and the implications for scoliosis screening: our duty for raising awareness and advocacy

Background A recently published NIH-funded study named “Bracing in Adolescent Idiopathic Scoliosis Trial” (BrAIST) affirmed the efficacy of bracing for moderate adolescent idiopathic scoliosis (AIS) and reduced surgical recommendations in braced patients. The implications of this study are numerous. BrAIST affirms the value of bracing, but also confirms the importance of wear time, and points t...

متن کامل

Guidelines on "Standards of management of idiopathic scoliosis with corrective braces in everyday clinics and in clinical research": SOSORT Consensus 2008

BACKGROUND Reported failure rates,(defined based on percentage of cases progressing to surgery) of corrective bracing for idiopathic scoliosis are highly variable. This may be due to the quality of the brace itself, but also of the patient care during treatment. The latter is sometimes neglected, even though it is considered a main determinant of good results among conservative experts of SOSOR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of children's orthopaedics

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 2015