Pulsed dye laser lithotripsy of bile duct stones.
نویسندگان
چکیده
Efficacy and safety of pulsed dye laser lithotripsy was tested in 25 consecutive patients in whom bile duct stones could not be extracted after endoscopic sphincterotomy. The patients had one to six (mean, 1.8) bile duct stones (diameter, 10-35 mm; mean, 18 mm) located in the common bile duct (18 cases), the intrahepatic bile ducts (6 cases), or in a long cystic duct stump (1 case). Different approaches were tested depending on the presence of a T tube and on the localization of the bile duct stones. When a T tube was present (7 cases), the lithotripsy was performed under direct vision using a choledochoscope inserted through the T-tube tract. In 18 patients without a T tube in place, the lithotripsy was performed under fluoroscopy using a retrograde approach in case of common bile duct stones (14 cases) or under choledochoscopy using a percutaneous transhepatic approach in case of intrahepatic bile duct stones (4 cases). Fragmentation of all the bile duct stones and a complete bile duct clearance were obtained in all 11 cases with procedures performed under direct vision as compared with only 5 of 14 cases with procedures under fluoroscopic control. Moreover, 6 of the 9 failures using the latter approach were offered another session using a choledochoscope inserted through a percutaneous transhepatic tract and were also successfully treated. No complication related to the laser beam was noted. It is concluded that pulsed dye laser lithotripsy of bile duct stones (that are unable to be removed by standard endoscopic techniques) is safe and efficacious provided that it is performed under direct vision. Technical refinements are needed before this procedure can be reliably performed under fluoroscopy.
منابع مشابه
Laser lithotripsy of difficult bile duct stones: results in 60 patients using a rhodamine 6G dye laser with optical stone tissue detection system.
INTRODUCTION Laser lithotripsy of bile duct stones has become a widely accepted endoscopic treatment modality for giant, impacted, or very hard stones. The procedure is usually carried out under direct endoscopic control in view of the potential risk of bile duct injuries in "blind" laser application. AIMS To investigate the use of a rhodamine 6G laser lithotriptor with an integrated optical ...
متن کاملLaser lithotripsy of diYcult bile duct stones: results in 60 patients using a rhodamine 6G dye laser with optical stone tissue detection system
Introduction—Laser lithotripsy of bile duct stones has become a widely accepted endoscopic treatment modality for giant, impacted, or very hard stones. The procedure is usually carried out under direct endoscopic control in view of the potential risk of bile duct injuries in “blind” laser application. Aims—To investigate the use of a rhodamine 6G laser lithotriptor with an integrated optical st...
متن کاملEndoscopic laser lithotripsy for complicated bile duct stones: is cholangioscopic guidance necessary?
BACKGROUND Endoscopic papillotomy is successful in more than 95% of the cases of choledocholithiasis. For patients with difficult bile duct stones not responding to mechanical lithotripsy, different methods for stone fragmentation have been developed. AIM To compare the results of laser lithotripsy with a stone-tissue recognizing system, when guided by fluoroscopy only or by cholangioscopy. ...
متن کاملExperimental cholelitholysis with the pulsed tunable dye laser.
This study evaluates the pulsed tunable dye laser with wavelength 504 nm, frequency 10 Hz, and pulse width 1.2 microseconds for cholelitholysis. Power of 10-40 kW was directed through a 250-microns quartz fiber optic to ablate 55 gallstones (removed from 14 patients). The fiber was positioned in direct contact with the stones under saline. Power delivery was begun at 10 kW and increased in 10-k...
متن کاملLaserlithotripsy of common bile duct stones.
Endoscopic retrograde laser lithotripsy of common bile duct stones is a new technique which can be carried out through the endoscope without anaesthesia using ordinary endoscopic equipment. In the method described here a flashlamp pulsed Neodymium YAG laser (wave length 1064 nm) was used. Light energy was transmitted along a highly flexible quartz fibre with a diameter of 0.2 mm. This new techn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gastroenterology
دوره 100 6 شماره
صفحات -
تاریخ انتشار 1991