Quantification of myocardial infarct size by thallium-201 single-photon emission computed tomography: experimental validation in the dog.

نویسندگان

  • F Prigent
  • J Maddahi
  • E V Garcia
  • Y Satoh
  • K Van Train
  • D S Berman
چکیده

To evaluate the potential advantages of thallium-201 (201T1) single-photon emission computerized tomography (SPECT) to assess myocardial infarct size in the experimental animal, six normal dogs and 14 dogs with 6 to 8 hr closed-chest coronary occlusion (eight left anterior descending and six left circumflex) were studied. Ten minutes after intravenous administration of 2 mCi of 201T1, 30 projections were obtained over 180 degrees. The dogs were killed and their hearts sliced and stained by triphenyl tetrazolium chloride (TTC). Pathologic infarct size was calculated for each slice and for the entire left ventricular myocardium as percent weight. Tomograms were quantified by automatically generating maximum-count circumferential profiles, which were compared with normal limit profiles derived from the six normal dogs. Tomographic infarct size was defined as the percentage of circumferential points falling below normal for each tomogram. SPECT and TTC infarct size on 71 slices correlated highly (mean +/- SD 27.9 +/- 23.4% and 26.7 +/- 25.3%, respectively; r = .93, p less than .001, SEE = 9.4%). To determine SPECT infarct size as percent total left ventricular myocardial weight, infarct sizes from each slice were added to one another after each was multiplied by a coefficient that reflected the contribution of that slice to the total left ventricular weight. SPECT and TTC infarct size for the entire left ventricle correlated closely (mean +/- SD 20.5 +/- 7.6% and 19.3 +/- 8.3%, respectively; r = .86, p less than .001, SEE = 4.5%). It is concluded that 201T1 SPECT is a valid method for the noninvasive assessment of experimental myocardial infarct size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New method of estimating myocardial infarct size using technetium-99m pyrophosphate and thallium-201 dual single photon emission computed tomography imaging.

A new method was devised to estimate infarct size using dual single photon emission computed tomography with thallium-201 and technetium-99m pyrophosphate. Designating the ratio of infarct area to whole myocardial volume as %MI, the correlation of %MI with other markers of left ventricular dysfunction was examined: peak creatine kinase, ejection fraction and left ventricular asynergy. As %MI co...

متن کامل

Quantification of myocardial infarct size by thallium - 201 single - photon emission computed tomography : experimental validation in the dog FLORENCE PRIGENT

To evaluate the potential advantages of thallium-201 (201T1) single-photon emission computerized tomography (SPECT) to assess myocardial infarct size in the experimental animal, six normal dogs and 14 dogs with 6 to 8 hr closed-chest coronary occlusion (eight left anterior descending and six left circumflex) were studied. Ten minutes after intravenous administration of 2 mCi of 201T1, 30 projec...

متن کامل

Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon-emission computed tomography, thallium-201, and indium 111-monoclonal antimyosin Fab.

Single photon-emission tomography (SPECT) and indium 111-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous inje...

متن کامل

Exercise four hour redistribution thallium-201 single photon emission computed tomography and exercise induced ST segment elevation in detecting the viable myocardium in patients with acute myocardial infarction.

OBJECTIVE To investigate the specificity and sensitivity of the combination of redistribution in exercise thallium-201 single photon emission computed tomography (SPECT) and exercise induced ST elevation for detecting the viable myocardium in patients with acute myocardial infarction. DESIGN 37 patients were studied within seven weeks of onset of Q wave myocardial infarction (anterior in 22, ...

متن کامل

Submaximal exercise thallium-201 SPECT for assessment of interventional therapy in patients with acute myocardial infarction.

Submaximal thallium-201 stress testing has been shown to provide important diagnostic and prognostic information in patients with acute myocardial infarction. The purpose of this investigation was to evaluate the diagnostic value of early submaximal stress testing and thallium-201 single photon emission computed tomography (SPECT) after interventional therapy. Scintigraphic results from 56 pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 74 4  شماره 

صفحات  -

تاریخ انتشار 1986