The Potential Effects of a Biofeedback Writing Exercise on Radial Artery Blood Flow and Neck Mobility

نویسندگان

  • Rob L. Krullaards
  • Johan J. M. Pel
  • Chris J. Snijders
  • Gert-Jan Kleinrensink
چکیده

BACKGROUND It has been suggested that sustained contraction of the deep neck muscles may reduce axial cervical range of motion (CROM) and radial artery blood flow velocity (vrad.art.mean). No studies have reported both phenomena in relation to acute hand, shoulder or neck trauma. PROCEDURES The CROM and vrad.art.mean were measured in 20 police officers prior to and immediately after a 2-hours drive on a motorcycle and immediately after a 1-minute writing exercise using biofeedback. The CROM was measured using separate inclinometers and the vrad.art.mean was measured in both arms just proximal to the wrist using echo-Doppler. FINDINGS During the study, one officer had a motorcycle accident resulting in acute symptoms of neck trauma. His vrad.art.mean was acutely reduced by 73% (right arm) and 45% (left arm). Writing with biofeedback increased his vrad.art.mean by 150% (right arm) and 80% (left arm). In the remaining 19 officers, the CROM to the right was significantly increased after the 2-hours driving task (p<0.05; paired subject t-test). Writing with biofeedback increased their CROM in both directions and vrad.art.mean in both arms (p<001). CONCLUSIONS A 2-hours drive showed modest physical changes in the upper extremities. Biofeedback in writing tasks might relate to the influence of relaxation and diverting attention for neck mobility and arterial blood flow improvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of reactive artery hyperaemia on the radial strain of the brachial artery: Definition of optimum cuff position

Instruction: Measurement of brachial artery diameter variation by ultrasound methods has commonly been used to test the endothelial function. It is known that the artery diameter is increased by flow stimulation. Therefore in the present study, the effect of external obstruction, as flow stimulation, on the radial strain of the brachial artery was assessed. Also the biomechanical behavior of...

متن کامل

MHD Flow of Blood through Radially Non-symmetric Stenosed Artery: a Hershcel-Bulkley Model (RESEARCH NOTE)

The purpose of this study is to develop a mathematical model for studying the magnetic field effect on blood flow through an axially non-symmetric but radially symmetric atherosclerotic artery. Herschel-Bulkley equation has been taken to represent the non-Newtonian character of blood. The response of magnetic field, stenosis height, shape parameter on velocity, volumetric flow rate in stenotic ...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

Measuring the Nitroglycerine-Induced Vasodilation in Carotid Arteries

Introduction: Nitroglycerin is a fast-acting drug that rapidly dilates coronary arteries and thus increases blood flow to these vessels, and increases the blood flow through the lateral vessels to low blood areas. It also reduces both end diastolic pressure and volume of the left ventricular. However, the effect of nitroglycerin on the circulation hemodynamic is not known. Caro...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2009