Intraocular Pressure Course During the Femtosecond Laser-Assisted Cataract Surgery in Porcine Cadaver Eyes.

نویسندگان

  • Philipp Sperl
  • Clemens Strohmaier
  • Hannes Kraker
  • Karolina Motloch
  • Markus Lenzhofer
  • Sarah Moussa
  • Herbert A Reitsamer
چکیده

Purpose Femtosecond laser-assisted cataract surgery (FLACS) is an increasingly common procedure. Most laser systems require corneal applanation and thereby increase intraocular pressure (IOP). The purpose of the present study was to evaluate the IOP changes that occur during the FLACS procedure performed using the Catalys femtosecond laser system. Methods IOP was measured by direct cannulation of the vitreous body of porcine cadaver eyes (N = 20). By inserting a second cannula connected to a water column, all the eyes were set to a baseline IOP of 20 mm Hg. The eyes were lifted by custom-made stands to achieve the appropriate height and position under the Catalys system. The standard FLACS procedure was performed using varying fragmentation times to assess the influence of tissue fragmentation times on IOP peaks. Results We identified significant IOP elevations from baseline IOP levels during all steps of the FLACS procedure (baseline: 20.28 ± 1.32 mm Hg; vacuum: 34.48 ± 4.21 mm Hg; capture: 47.90 ± 13.02 mm Hg; lock: 48.41 ± 9.04 mm Hg; analysis: 47.15 ± 5.97 mm Hg; capsulotomy: 45.74 ± 6.52 mm Hg; fragmentation: 48.41 ± 6.80 mm Hg; end: 17.81 ± 1.61 mm Hg; all P < 0.001). Furthermore, the tissue fragmentation time had a significant effect on the peak IOP values detected (R = 0.62, P = 0.04, n = 9). Conclusions The present study reveals significant IOP increases during FLACS procedures carried out using the Catalys system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical patient interface in femtosecond laser-assisted cataract surgery: contact corneal applanation versus liquid immersion.

PURPOSE To compare 2 optical patient interface designs used for femtosecond laser-assisted cataract surgery. SETTING Optimedica Corp., Santa Clara, California, USA, and Centro Laser, Santo Domingo, Dominican Republic. DESIGN Experimental and clinical studies. METHODS Laser capsulotomy was performed during cataract surgery with a curved contact lens interface (CCL) or a liquid optical imme...

متن کامل

Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery.

PURPOSE To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. METHODS Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addit...

متن کامل

Femtosecond laser capsulotomy.

PURPOSE To evaluate a femtosecond laser system to create the capsulotomy. SETTING Porcine and cadaver eye studies were performed at OptiMedica Corp., Santa Clara, California, USA; the human trial was performed at the Centro Laser, Santo Domingo, Dominican Republic. DESIGN Experimental and clinical study. METHODS Capsulotomies performed by an optical coherence tomography-guided femtosecond...

متن کامل

Preliminary Results of Femtosecond Laser-assisted Cataract Surgery in a Private Clinic in Iran

PURPOSE To report the preliminary results of femtosecond laser-assisted cataract surgery in Iranian patients. METHODS This prospective case series included 21 eyes of 21 patients with cataract. Mean patient age was 66.7 ± 10 years. The patients underwent femtosecond-laser assisted cataract surgery (VICTUS Femtosecond Laser Platform: Bausch + Lomb) and intraocular lens (IOL) implementation in ...

متن کامل

Suprachoroidal hemorrhage during femtosecond laser assisted cataract surgery

Purpose To describe a case of suprachoroidal hemorrhage that occurred during femtosecond laser assisted cataract surgery (FLACS). Observations A 67-year-old woman with high myopia underwent FLACS. Following two unsuccessful attempts at docking due to interface air bubbles, the third attempt was successful. Laser treatment and cataract surgery proceeded uneventfully until intraocular lens (IOL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 58 14  شماره 

صفحات  -

تاریخ انتشار 2017