Interleaved spiral cine coronary artery velocity mapping.

نویسندگان

  • J Keegan
  • P Gatehouse
  • G Z Yang
  • D Firmin
چکیده

Navigator-echo controlled interleaved spiral cine coronary-artery velocity maps were acquired in eight free-breathing volunteers. Good quality data were achieved in all subjects with phasic flow being clearly demonstrated. The improved efficiency of spiral k-space coverage compared to that of more conventional spin-warp techniques resulted in a mean scan time for 256 x 256 pixel-matrix studies of 94 sec (range 69 - 123 sec, SD = 20 sec), the navigator acceptance rate being typically 40-45%. Repeat scans in five subjects showed a high degree of reproducibility, with no significant differences occurring in the peak velocities (14.6+/-1.4 cm/sec vs. 14.5+/-1.5 cm/sec, P = ns) nor in the mean velocities measured over all cine phases (8.3+/-2.1 cm/sec vs. 8.7+/-1.6 cm/sec, P = ns). The potential benefits of using this sequence for assessing coronary blood flow and flow reserve are discussed. Magn Reson Med 43:787-792, 2000.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of spiral and FLASH phase velocity mapping, with and without breath-holding, for the assessment of left and right coronary artery blood flow velocity.

PURPOSE To develop high temporal resolution coronary artery spiral phase velocity mapping sequences and to compare the results obtained with those from FLASH sequences. MATERIALS AND METHODS Velocity curves were obtained in eight left and eight right coronary arteries using breath-hold interleaved spiral (BH_SP), free-breathing interleaved spiral (FB_SP), breath-hold segmented FLASH (BH_FL), ...

متن کامل

Validation of high temporal resolution spiral phase velocity mapping of coronary artery blood flow against Doppler flow wire

Background The temporal pattern of coronary artery flow velocity through the cardiac cycle provides important information about coronary haemodynamics. The ‘gold standard’ for coronary artery velocity assessment is the Doppler flow wire which is inserted directly into the coronary artery under X-ray fluoroscopic guidance, which is invasive, uses ionising radiation and has a small but significan...

متن کامل

Spiral phase velocity mapping of left and right coronary artery blood flow: correction for through-plane motion using selective fat-only excitation.

PURPOSE To develop a method of correcting both right and left coronary artery flow velocities for the through-plane motion of the vessel, in order to allow details in the temporal flow profiles to be viewed. MATERIALS AND METHODS The methods developed use selective excitation and velocity mapping of the epicardial fat surrounding the artery, either in a separate acquisition (temporal resoluti...

متن کامل

Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation.

PURPOSE Serial change of the coronary flow velocity reserve was evaluated with fast velocity-encoded cine magnetic resonance imaging (MRI) for noninvasive detection of restenosis after coronary stent implantation. METHOD In total, 60 MRI flow studies were performed in 10 patients with coronary artery disease who undersvent elective successful stent implantation to the lesion in the proximal l...

متن کامل

Inter-study reproducibility of interleaved spiral phase velocity mapping of renal artery haemodynamics

BACKGROUND Qualitative and quantitative assessment of renal blood flow is valuable in the evaluation of patients with renal and renovascular diseases as well as in patients with heart failure. The temporal pattern of renal flow velocity through the cardiac cycle provides important information about renal haemodynamics. High temporal resolution interleaved spiral phase velocity mapping could pot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 2000