Pixel array detector for X-ray free electron laser experiments

نویسندگان

  • Hugh T. Philipp
  • Marianne Hromalik
  • Mark Tate
  • Sol M. Gruner
چکیده

X-ray free electron lasers (XFELs) promise to revolutionize X-ray science with extremely high peak brilliances and femtosecond X-ray pulses. This will require novel detectors to fully realize the potential of these new sources. There are many current detector development projects aimed at the many challenges of meeting the XFEL requirements [1,2]. This paper describes a pixel array detector (PAD) that has been developed for the Coherent X-ray Imaging experiment at the Linac Coherent Light Source (LCLS) at the SLAC National Laboratory [3]. The detector features 14-bit in-pixel digitization; a 2-level in-pixel gain setting that can be used tomake an arbitrary 2-D gain pattern that is adaptable to a particular experiment; the ability to handle instantaneous X-ray flux rates of 10 photons per second; and continuous frames rates in excess of 120 Hz. The detector uses direct detection of X-rays in a silicon diode. The charge produced by the diode is integrated in a pixilated application specific integrated circuit (ASIC) which digitizes collected holes with single X-ray photon capability. Each ASIC is 194 185 pixels, each pixel is 110 mm 110 mm on a side. Each pixel can detect up to 2500 X-rays per frame in low-gain mode, yet easily detects single photons at high-gain. Cooled, single-chip detectors have been built and meet all the required specifications. SLAC National Laboratory is engaged in constructing a tiled, multi-chip 1516 1516 pixel detector. & 2010 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments.

This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 10(14) photon/mm(2). The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 μ...

متن کامل

Pixel Array Detector for the Capture of Femtosecond Duration X-ray Images

An imaging Pixel Array Detector (PAD) is being developed to record x-ray scattering images from single particles at the SLAC Linac Coherent Light Source (LCLS) x-ray free electron laser. The LCLS will deliver x-ray pulses of 5 – 200 femtosecond duration 120 times per second. Proposed experiments require that the scatter from each pulse be independently recorded. This necessitates a detector wit...

متن کامل

Synchrotron Area X-ray Detectors, Present and Future

X-ray experiments are very frequently detector limited at today’s storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day sources were outgrowths of technologies initially developed for the medical and astronomical communities, r...

متن کامل

Observation of femtosecond molecular dynamics via pump–probe gas phase x-ray scattering

We describe a gas-phase x-ray scattering experiment capable of capturing molecular motions with atomic spatial resolution and femtosecond time resolution. X-ray free electron lasers can deliver intense x-ray pulses of ultrashort duration, making them suitable to study ultrafast chemical reaction dynamics in an ultraviolet pump, x-ray probe scheme. A cell diffractometer balances sample flow with...

متن کامل

Potential Beneficial Effects of Electron-Hole Plasmas Created in Silicon Sensors by XFEL-Like High Intensity Pulses for Detector Development

There is a compelling need for a high frame rate imaging detector with a wide dynamic range, from single xrays/pixel/pulse to > 106 x-rays/pixel/pulse, that is capable of operating at both x-ray free electron laser (XFEL) and 3rd generation sources with sustained fluxes of > 1011 x-rays/pixel/s [1, 2, 3]. We propose to meet these requirements with the High Dynamic Range Pixel Array Detector (HD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011