Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography.

نویسندگان

  • Dirk Faber
  • Freek van der Meer
  • Maurice Aalders
  • Ton van Leeuwen
چکیده

From calibrated, weakly scattering tissue phantoms (2-6 mm-1), we extract the attenuation coefficient with an accuracy of 0.8 mm-1 from OCT data in the clinically relevant 'fixed focus' geometry. The data are analyzed using a single scattering model and a recently developed description of the confocal point spread function (PSF). We verify the validity of the single scattering model by a quantitative comparison with a multiple scattering model, and validate the use of the PSF on the calibrated samples. Implementation of this model for existing OCT systems will be straightforward. Localized quantitative measurement of the attenuation coefficient of different tissues can significantly improve the clinical value of OCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are quantitative attenuation measurements of blood by optical coherence tomography feasible?

We present optical coherence tomography (OCT) measurements on fully physiologically oxygenated blood samples of varying hematocrit. We show that attenuation coefficients cannot be extracted quantitatively using the currently accepted models for the OCT signal from scattering media, because the confidence intervals obtained in the fitting procedure cannot be used as reliable uncertainty estimate...

متن کامل

Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography.

The use of spectroscopic optical coherence tomography to assess hemoglobin oxygen saturation of whole blood is investigated. We propose to use the differential attenuation coefficient to determine the degree of saturation. Our data show qualitative agreement between the measured differential attenuation coefficients as a function of saturation and predictions based on the oxygen-saturation-depe...

متن کامل

Quantitative comparison of contrast and imaging depth of ultrahigh-resolution optical coherence tomography images in 800–1700 nm wavelength region

We investigated the wavelength dependence of imaging depth and clearness of structure in ultrahigh-resolution optical coherence tomography over a wide wavelength range. We quantitatively compared the optical properties of samples using supercontinuum sources at five wavelengths, 800 nm, 1060 nm, 1300 nm, 1550 nm, and 1700 nm, with the same system architecture. For samples of industrially used h...

متن کامل

Optical phantoms of varying geometry based on thin building blocks with controlled optical properties

irk J. Faber niversity of Amsterdam cademic Medical Center epartment of Biomedical Engineering and Physics and pththalmology Department msterdam, 1100 DE Netherlands Abstract. Current innovations in optical imaging, measurement techniques, and data analysis algorithms express the need for reliable testing and comparison methods. We present the design and characterization of silicone elastomer-b...

متن کامل

ptical phantoms of varying geometry based on thin uilding blocks with controlled optical properties

irk J. Faber niversity of Amsterdam cademic Medical Center epartment of Biomedical Engineering and Physics and pththalmology Department msterdam, 1100 DE Netherlands Abstract. Current innovations in optical imaging, measurement techniques, and data analysis algorithms express the need for reliable testing and comparison methods. We present the design and characterization of silicone elastomer-b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 12 19  شماره 

صفحات  -

تاریخ انتشار 2004