X-ray imaging using amorphous selenium: determination of Swank factor by pulse height spectroscopy.
نویسندگان
چکیده
The use of photoconductors, especially amorphous selenium (a-Se), in x-ray imaging is currently of interest. A critical performance parameter of an imaging detector is the Swank factor for degradation of the signal to noise ratio, or DQE(0), due to variations in the detector response. The Swank factor is evaluated from measured pulse height spectra generated by the absorption of monoenergetic x-ray photons. The spectra show an additional width over previous theoretical expectations, but the Swank factor is still close to the high values previously predicted theoretically.
منابع مشابه
Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: application to pulse-height spectroscopy in a-Se.
PURPOSE The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. METHODS A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The char...
متن کاملFundamental x-ray interaction limits in diagnostic imaging detectors: frequency-dependent Swank noise.
A frequency-dependent x-ray Swank factor based on the "x-ray interaction" modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI2) for incident photon energies between 10 and 150 keV and variou...
متن کاملUnfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
متن کاملSignal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors.
Image quality in diagnostic x-ray imaging is ultimately limited by the statistical properties governing how, and where, x-ray energy is deposited in a detector. This in turn depends on the physics of the underlying x-ray interactions. In the diagnostic energy range (10-100 keV), most of the energy deposited in a detector is through photoelectric interactions. We present a theoretical model of t...
متن کاملDetermination of the optical properties of amorphous selenium films by a classical damped oscillator model.
Amorphous selenium films were produced by vacuum evaporation onto glass and aluminum substrates. The chemical composition of the films and interfaces were studied using scanning Auger electron spectroscopy. To gain some insight into the optical properties of the selenium films, we used the classical oscillator model to fit the transmittance spectrum.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 25 5 شماره
صفحات -
تاریخ انتشار 1998