3D z-shim method for reduction of susceptibility effects in BOLD fMRI.

نویسنده

  • G H Glover
چکیده

Susceptibility-induced magnetic field gradients (SFGs) perpendicular to the slice plane often result in signal dropout in blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) experiments. Two-dimensional (2D) z-shim methods reduce these effects by acquiring multiple images with different slice refocusing gradient areas. In this work a 3D z-shim method is introduced as a more efficient alternative. The technique augments the k-space data for a conventional 3D phase encoding acquisition with N additional lines that extend the k(z) coverage sufficiently to sample k-space fully in regions with SFGs. Multiple subsets of these data are reconstructed using a sliding window that provides N +1 z-shim images. Fewer total acquisitions are required than with the 2D method for the same coverage, and finer z-shim steps are obtained. The technique is demonstrated with a motor task using intentionally introduced SFGs and compared with the 2D method. The results confirm increased BOLD SNR and activation with the new method in good agreement with theory. Magn Reson Med 42:290-299, 1999.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal EPI parameters for reduction of susceptibility-induced BOLD sensitivity losses: a whole-brain analysis at 3 T and 1.5 T.

Most functional magnetic resonance imaging (fMRI) studies record the blood oxygen level-dependent (BOLD) signal using fast gradient-echo echo-planar imaging (GE EPI). However, GE EPI can suffer from substantial signal dropout caused by inhomogeneities in the static magnetic field. These field inhomogeneities occur near air/tissue interfaces, because they are generated by variations in magnetic ...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation.

Susceptibility-induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient-echo-based functional MRI (fMRI) studies. Although conventional z-shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z-shim technique with high imagi...

متن کامل

Multiple gradient- and spin-echo EPI acquisition technique with z-shimming to compensate for susceptibility-induced off- resonance effects

INTRODUCTION – Images obtained with gradient-echo echo planar imaging (GRE-EPI) suffer from magnetic field variations within the brain, such as in regions adjacent to air-tissue interfaces. In these regions, magnetic field inhomogeneities cause spins to dephase more rapidly, resulting in signal dropouts. Thus, conventional GRE-EPI pulse sequences used for dynamic susceptibility-contrast perfusi...

متن کامل

A Bit of a Mouth Full: Susceptibility Artifact Reduction Using Diamagnetic Passive Shims

Local diamagnetic passive shims can substantially reduce brain BO inhomogeneity, resulting in greatly improved signal loss and image distortion artifacts in BOLD fMRI data. For a standard fMRI-type EPI sequence, placement of 5.5 cm3 of diamagnetic material in the mouth reduced by 74% the number of voxels in the inferior frontal cortex experiencing >75% signal loss. A diamagnetic earplug reduced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 1999