Validation of blood product irradiation doses.

نویسندگان

  • T Cheung
  • M Butson
  • P K Yu
چکیده

Dosimetry of blood irradiation using x-ray beams on a medical linear accelerator has been studied to evaluate the accuracy of a diode detector and the delivery achievable. Variations in applied doses for a standard dual field 6 MV x-ray are measured with a commercial diode detector. Results show that the diode detector measured applied in vitro doses to within 5.4% (2 standard deviations (2 SD)) of those calculated with a collapsed-cone convolution treatment-planning computer for a sample of 100 blood irradiations. Experiments involving the packing procedure of the blood products in the blood box were performed. It was found that a large proportion of the variation in the predicted and measured dose was due to the compacting of the scatter material at the base of the blood box (over a 6 month period) producing a higher density below the blood than originally scanned; hence an overall reduction of delivered dose was observed. The diode measurements (which provide an immediate printout) are recommended in conjunction with a film dosimeter such as radiochromic film, which still provides a back-up dose monitor and a visual reminder that the blood has been irradiated. It is also recommended that the blood box be completely evacuated of all scatter material every month and the base be carefully repacked to provide uniform scatter material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اثر پرتوالکترونی برخواص فیزیکی وشیمیایی و ویژگی های حسی بستنی سنتی

Introduction: Due to the increasing use of irradiation in food safety as an efficient and supplement method, it is needed to investigate effects of this new technology on the apparent and organoleptic characteristics of different products. Because primarily thing that attracts the attention of the customer to buy a food product is its appearance characteristics. The aim of this study was to det...

متن کامل

Blood irradiation with accelerator produced electron beams.

Blood and blood products are irradiated with gamma rays to reduce the risk of graft versus host disease (GVHD). A simple technique using electron beams produced by a medical linear accelerator has been studied to evaluate irradiation of blood and blood products. Variations in applied doses for a single field 20 MeV electron beam are measured in a phantom study. Doses have been verified with ion...

متن کامل

Irradiation as a phytosanitary treatment for Aspidiotus destructor (Homoptera: Diaspididae).

Coconut scale, Aspidiotus destructor Signoret (Homoptera: Diaspididae), is a quarantine pest of banana (Musa spp.) and many tropical crops. Irradiation was examined as a potential phytosanitary treatment to control coconut scale. Dose-response tests were conducted with second-stage nymphs, adult females without eggs, and adult females with eggs at a series of irradiation doses between 60 and 20...

متن کامل

CYTOGENETIC BIOMONITORING OF 65 RADIOLOGY TECHNOLOGISTS OCCUPATIONALLY EXPOSED TO CHRONIC DOSES OF X-IRRADIATION IN IRAN

The frequency of chromosomal aberrations was studied in the peripheral blood lymphocytes of 65 radiology technologists CRT) working at hospitals chronically exposed to x-rays. Although film dosimetry did not show the maximal annual permitted dose in any of the examined subjects, cytogenetic analysis detected fairly high levels of chromosomal aberrations in R T compared to unexposed controls...

متن کامل

Effects of Gamma Irradiation on Proliferation and IL-5 Production of Peripheral Blood Lymphocytes

Gamma irradiation is routinely used for suppression of lymphocyte function in transfusion and transplantation procedures. In recent years, some investigators focused on the effects of ionizing radiation on special aspects of lymphocyte function and considered the possibility of its clinical application for treatment of some immunological disorders. In this study, we evaluated the effects of fiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 10  شماره 

صفحات  -

تاریخ انتشار 2001