Untargeted Identification of Organo-Bromine Compounds in Lake Sediments by Ultrahigh-Resolution Mass Spectrometry with the Data-Independent Precursor Isolation and Characteristic Fragment Method.

نویسندگان

  • Hui Peng
  • Chunli Chen
  • David M V Saunders
  • Jianxian Sun
  • Song Tang
  • Garry Codling
  • Markus Hecker
  • Steve Wiseman
  • Paul D Jones
  • An Li
  • Karl J Rockne
  • John P Giesy
چکیده

While previous studies have found that unknown natural and synthetic organo-bromine compounds (NSOBCs) contributed more than 99% of the total organic bromine (Br) in the environment, there was no efficient method for untargeted screening to identify NSOBCs in environmental matrixes. A novel untargeted method for identifying NSOBCs, based on ultrahigh-resolution mass spectrometry (UHRMS) with the Q Exactive instrument was developed. This method included a data-independent precursor isolation and characteristic fragment (DIPIC-Frag) procedure to identify NSOBCs. A total of 180 successive 5-m/z-wide windows were used to isolate precursor ions. This resulted in a sufficient dynamic range and specificity to identify peaks of Br fragment ions for analysis. A total of 2520 peaks of NSOBC compounds containing Br were observed in sediments from Lake Michigan, United States. A new chemometric strategy which combined chromatographic profiles, isotopic peaks, precursor isolation window information, and intensities was used to identify precursor ions and chemical formulas for detecting NSOBCs. Precursor ions for 2163 of the 2520 NSOBCs peaks (86%) were identified, and chemical formulas for 2071 NSOBCs peaks (82%) were determined. After exclusion of isotopic peaks, 1593 unique NSOBCs were identified and chemical formulas derived for each. Most of the compounds identified had not been reported previously and had intensities which were 100- to 1000-fold greater than the congeners of polybrominated diphenyl ethers (PBDEs). In extracts of sediments, these compounds exhibited variations in intensities (<10(3) to ∼10(8)), m/z values (170.9438-997.5217), retention times on a C18 column (1.0-29.3 min), and the number of Br atoms (1-8). Generally, compounds with greater m/z values had longer retention times and greater numbers of Br atoms. Three compounds were used in a proof-of-concept experiment to demonstrate that structures of some of the screened NSOBCs could be further predicted by combining searching of database libraries and high-resolution MS(2) spectra.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated molecular formula determination by tandem mass spectrometry (MS/MS).

Automated software was developed to analyze the molecular formula of organic molecules and peptides based on high-resolution MS/MS spectroscopic data. The software was validated with 96 compounds including a few small peptides in the mass range of 138-1569 Da containing the elements carbon, hydrogen, nitrogen and oxygen. A Micromass Waters Q-TOF Ultima Global mass spectrometer was used to measu...

متن کامل

Broad spectrum drug screening using liquid chromatography quadrupole time of flight mass spectrometry: How valuable is retention time for identifying compounds?

Background: Broad spectrum drug screening, also known as systematic toxicological analysis or general unknown screening (GUS), is a method commonly used by clinical and forensic toxicology laboratories to detect a variety of drugs and metabolites in biological fluids. Recently, there has been much interest in liquid chromatography-high resolution mass spectrometry (LCHRMS) techniques for GUS as...

متن کامل

Comprehensive Analysis for Organo-bromine Compounds in Environmental Samples with GC/MS (EI/NCI)

Introduction. Brominated flame retardants (BFRs) are chemicals that are added to polymers that are used in plastics, rubber, textiles and other materials to prevent fires. Similarly to other organic pollutants, BFRs have persistence and bioaccumulation potential in organisms. Recently, BFRs have become of increasing concern in environmental samples, due to the increase of the concentration of B...

متن کامل

Bar Coding MS Spectra for Metabolite Identification

Metabolite identifications are most frequently achieved in untargeted metabolomics by matching precursor mass and full, high-resolution MS spectra to metabolite databases and standards. Here we considered an alternative approach for establishing metabolite identifications that does not rely on full, high-resolution MS spectra. First, we select mass-to-charge regions containing the most informat...

متن کامل

Bar Coding MS2 Spectra for Metabolite Identification

Metabolite identifications are most frequently achieved in untargeted metabolomics by matching precursor mass and full, high-resolution MS(2) spectra to metabolite databases and standards. Here we considered an alternative approach for establishing metabolite identifications that does not rely on full, high-resolution MS(2) spectra. First, we select mass-to-charge regions containing the most in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 87 20  شماره 

صفحات  -

تاریخ انتشار 2015