Comparison of Choroidal Vascularity Markers on Optical Coherence Tomography Using Two-Image Binarization Techniques.
نویسندگان
چکیده
Purpose To compare the agreement between optical coherence tomography (OCT)-based choroidal vascularity markers measured by two previously reported image binarization techniques. Methods Spectral-domain OCT using enhanced-depth imaging was performed in 100 eyes from 52 normal subjects. Choroidal images were binarized to luminal area and stromal area using two different algorithms. Choroidal vascularity marker was defined as the ratio of luminal area to total choroidal area and they were termed "luminal/choroidal area ratio (L/C ratio)" and "choroidal vascularity index (CVI)" per the algorithm. The agreement between choroidal vascularity markers measured by the two techniques was compared using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results The mean values of choroidal vascularity markers were 70.12% (range, 56.76%-78.55%) for CVI and 67.44% (range, 51.09%-81.31%) for L/C ratio. Low level of absolute agreement between the two binarization techniques was reflected by an adjusted ICC of 0.353 using linear mixed model with age, sex, and spherical equivalent as covariates. Conclusions There was discrepancy between measurements of choroidal vascularity using two commonly adopted image binarization techniques. It remained unclear what was the true choroidal vascularity and which binarization algorithm was more accurate. Future studies with enhanced image quality and improved image analysis algorithm are required to decipher the ground truth for choroidal vascularity.
منابع مشابه
Comparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography
Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...
متن کاملChoroidal Vascularity Index in Vogt-Koyanagi-Harada Disease: An EDI-OCT Derived Tool for Monitoring Disease Progression
PURPOSE We assessed the application of the choroidal vascularity index (CVI) in the follow-up of Vogt-Koyanagi-Harada disease (VKH) patients derived from image binarization of enhanced depth imaging optical coherence tomography (EDI-OCT) images with Fiji software. Our secondary objective was to derive the retinochoroidal vascularity index based on en face fundus fluorescein and indocyanine gree...
متن کاملChoroidal vascularity index as a measure of vascular status of the choroid: Measurements in healthy eyes from a population-based study.
The vascularity of the choroid has been implicated in the pathogenesis of various eye diseases. To date, no established quantifiable parameters to estimate vascular status of the choroid exists. Choroidal vascularity index (CVI) may potentially be used to assess vascular status of the choroid. We aimed to establish normative database for CVI and identify factors associated with CVI in healthy e...
متن کاملShort-term changes of choroidal vascular structures after phacoemulsification surgery
BACKGROUND To evaluate the changes of choroidal vascular structures in patients after phacoemulsification surgery. METHODS A self-control study was conducted on 36 eyes of 36 patients who had uneventful phacoemulsification. Choroidal images were acquired preoperatively, 7 days (D7), 1 month (M1), and 3 months (M3) after surgery from enhanced depth imaging (EDI) optical coherence tomography (O...
متن کاملSpeckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images
Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 59 3 شماره
صفحات -
تاریخ انتشار 2018