The Use of a Plastic Guide Improves the Safety and Reduces the Duration of Endotracheal Intubation in the Pig
نویسندگان
چکیده
The successful endotracheal intubation of pigs using the standard orotracheal method is challenging and technically difficult, because of the pig's oral anatomy and the presence of excess tissue in the oropharyngeal region. Hence, the operator, who is usually an anesthetist, requires extensive training in order to successfully perform the procedure in pigs. In this report, we describe a safe and quick method of successful endotracheal intubation in the pig using an 80-cm blunt-tipped plastic vascular catheter, when the pig is placed in ventral recumbency. Specifically, the use of this plastic guide wire shortened the duration of the procedure and reduced the risks of the procedure. Since the use of the guide wire also improves the ease of the procedure, its use will also enable inexperienced operators to perform successful first-time endotracheal intubation of pigs without causing injury.
منابع مشابه
Evaluation of the success rate and quality of teaching of tracheal intubation to medical students by using video laryngoscope
Background: Training of airway management and tracheal intubation skill in emergencies for resuscitation of patients are basic skills for medical students. However, the success rate of beginners in this skill is low. Video laryngoscopes are new devices that can increase the success of endotracheal intubation training. Methods: This clinical trial was conducted with 30 medical students who came...
متن کاملcomparison of endotracheal intubation with nerve block and intravenous injection
Introduction: As endotracheal intubation is the first action which must be done for serious and very ill patients , so any procrastination leads to dangerous consequences including aspiration and finally death. Routine method for endotracheal intubation is injection of intravascular diazepam- Pethidine and sometimes muscle relaxants , but these drugs in Patients with GCS under 7 cause more decr...
متن کاملEvaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materia...
متن کاملCommon Complications of Endotracheal Intubation in Newborns
Objective The purpose of this study was to assess the frequency of complications of endotracheal intubation (ETI) in neonates. Methods The newborns that were admitted and needed urgent or semi-urgent intubation were enrolled in this study over a 1 year period. Route for intubation in all cases were orotracheal. Cases were not routinely sedated or paralyzed. The patients were clinically and rad...
متن کاملA Comparative Study of the Efficacy of Surfactant Administration through a Thin Intratracheal Catheter and its Administration via an Endotracheal Tube in Neonatal Respiratory Distress Syndrome
Background: The cornerstone of the treatment of respiratory distress syndrome (RDS) is respiratory support and surfactant replacement therapy. The administration of surfactant through a thin intratracheal catheter is one of the methods used to reduce one of the standard technique complications of a surfactant injection (Intubation-Surfactant-Extubation method [INSURE]). The aim of this study wa...
متن کامل