Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator Lente implantável de collamer e laser de femtosegundo para miopia: comparação usando um simulador visual de óptica adaptativa

نویسندگان

  • Cari Pérez-ViVes
  • César albarrán-Diego
چکیده

The femtosecond laser (FS) is the most interesting technical de velopment in laser refractive surgery during the last few years. This technique was developed to create flaps for laser in situ keratomileusis (LASIK). The FS is a focusable infrared (1053 nm) laser that uses ultrafast pulses in the 100-femtosecond (100 x 10 second) range. The laser delivers closely spaced spots that can be focused at a preset depth to photodisrupt tissue within the corneal stroma, while causing minimal inflammation and collateral tissue damage. In the recent meta-analysis by Zhang et al. that compared femtosecond LASIK (F-LASIK) with mechanical microkeratome LASIK for myopia, no ABSTRACT Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MTF. ICL cases showed less spread out of PSF than F-LASIK cases. ICL cases showed better visual acuity values than F-LASIK cases for all pupils, contrasts, and myopic treatments (p<0.05). No statistically significant differences were found in contrast sensitivities between ICL and F-LASIK cases with -3-D myopia for both pupils for all evaluated spatial frequencies (p>0.05). For -6-D myopia, however, statistically significant differences in contrast sensitivities were found for both pupils for all evaluated spatial frequencies (p<0.05). Contrast sensitivities were better after ICL implantation than after F-LASIK. Conclusions: ICL implantation and F-LASIK provide good optical and visual quality, although the former provides better outcomes of MTF, PSF, visual acuity, and contrast sensitivity, especially for cases with large refractive errors and pupil sizes. These outcomes are related to the F-LASIK producing larger high-order aberrations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable collamer lens for high myopia: assessment of visual quality after implantation

Background: Patients with high myopia have higher risk of eye diseases. Currently, Implantable collamer lens (ICL) implantation is one of the widely used refractive intraocular lens surgical intervention methods. Purpose: To evaluate the effectiveness of implantable collamer lens (ICL) implantation in high myopia patients and the changes in wavefront aberrations after the operation. Methods: Th...

متن کامل

Comparison of clear lens extraction and collamer lens implantation in high myopia

AIM To compare the outcomes of clear lens extraction and collamer lens implantation in high myopia. PATIENTS AND METHODS Myopic patients younger than 40 years old with more than 12 diopters of myopia or who were not fit for laser-assisted in situ keratomileusis were included. Group 1 comprised patients undergoing clear lens extraction and Group 2 patients received the Visian implantable colla...

متن کامل

Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia

The aim of this study was to investigate the visual quality of the 2 kinds of intraocular lens: Visian implantable collamer lens (ICL) V4 and Visian ICL V4c implantations for high myopia.Twenty cases (20 eyes) with high myopia who received Visian ICL V4 implantation and 18 cases (18 eyes) with high myopia who received Visian ICL V4c implantation in our hospital from April 1, 2014 to November 31...

متن کامل

Evaluation of Phakic Posterior Chamber Intraocular Implantable Contact Lens for High Myopia

Purpose: To evaluate efficacy, predictability and safety of the surgical correction of high myopia using the phakic posterior chamber implantable collamer lens. Design: A prospective, nonrandomized, non-comparative interventional case series. Participants: Twenty seven eyes of fifteen patients aged from 20 to 46 years having high myopia were included. Intervention: STAAR modified collamer impla...