A clinical evaluation of the intubating laryngeal airway as a conduit for tracheal intubation in children.
نویسندگان
چکیده
BACKGROUND The air-Q Intubating Laryngeal Airway (ILA) (Cookgas LLC, Mercury Medical, Clearwater, FL) is a supraglottic airway device available in pediatric sizes, with design features to facilitate passage of cuffed tracheal tubes when used to guide tracheal intubation. We designed this prospective observational study of the ILA to assess the ease of its placement in paralyzed pediatric patients, determine its position and alignment to the larynx using a fiberoptic bronchoscope, gauge its efficacy as a conduit for fiberoptic intubation with cuffed tracheal tubes, and evaluate the ability to remove the ILA without dislodgement of the tracheal tube after successful tracheal intubation. METHODS One hundred healthy children, aged 6 months to 8 years, ASA physical status I to II, and scheduled for elective surgery requiring general endotracheal anesthesia were enrolled in this prospective study. Based on the manufacturer's guidelines, each patient received either a size 1.5 or 2.0 ILA according to their weight. The number of attempts for successful insertion, leak pressures, fiberoptic grade of view, number of attempts and time for tracheal intubation, time for ILA removal, and complications were recorded. RESULTS ILA placement, fiberoptic tracheal intubation, and ILA removal were successful in all patients. The size 1.5 ILA cohort had significantly higher rates of epiglottic downfolding compared with the size 2.0 ILA cohort (P < 0.001), despite adequate ventilation variables. When comparing fiberoptic grade of view to weight, a moderate negative correlation was found (r = -0.41, P < 0.001), indicating that larger patients tended to have better fiberoptic grades of view. The size 1.5 ILA cohort had a significantly longer time to intubation (P = 0.04) compared with the size 2.0 ILA cohort. However, this difference may not be clinically significant because there was a large overlap of confidence bounds in the average times of the size 1.5 ILA (27.0 ± 13.0 seconds) and size 2.0 ILA cohorts (22.7 ± 6.9 seconds). When comparing weight to time to tracheal intubation, a weak correlation that was not statistically significant was found (r = -0.17, P = 0.09), showing that time to intubation did not differ significantly according to weight, despite higher fiberoptic grades in smaller patients. CONCLUSIONS The ILA was easy to place and provided an effective conduit for tracheal intubation with cuffed tracheal tubes in children with normal airways. Additionally, removal of the ILA after successful intubation could be achieved quickly and without dislodgement of the tracheal tube. Because of the higher incidence of epiglottic downfolding in smaller patients, the use of fiberoptic bronchoscopy is recommended to assist with tracheal intubation through this device.
منابع مشابه
The new air-Q intubating laryngeal airway for tracheal intubation in children with anticipated difficult airway: a case series.
The air-Q intubating laryngeal airway (ILA) is a new supraglottic airway device which may overcome some limitations inherent to the classic laryngeal mask airway for tracheal intubation. We present a case series of patients with anticipated difficult airway in whom the air-Q ILA was successfully used as a conduit for fiberoptic intubation.
متن کاملComparison of Endotracheal Intubation Through I-gel and Intubating Laryngeal Mask Airway
Received: February 11, 2016 Revised: June 24, 2016 Accepted: June 24, 2016 Abstract: Background: Supraglottic airway devices (SADs) are very useful airway adjunct in managing anticipated and unanticipated difficult airway and can be used as a ventilating aid and as a conduit for tracheal intubation. The new versions of SADs like i-gel and intubating laryngeal mask airway (ILMA), have advantage ...
متن کاملUse of a laryngoscope, held sideways, as an aid in perforsming an intraoral glossopharyngeal nerve block
A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A manikin study.
متن کاملComparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study
Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...
متن کاملRetrospective audit of the air-Q intubating laryngeal airway as a conduit for tracheal intubation in pediatric patients with a difficult airway.
OBJECTIVES To assess the efficacy of the ILA as a conduit for tracheal intubation in pediatric patients with a difficult airway. AIM The primary goals of this retrospective audit were to assess the clinical performance of the ILA in pediatric patients with a difficult airway, expand on our initial favorable experience with this device, and collect pilot data for future prospective and compari...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 112 1 شماره
صفحات -
تاریخ انتشار 2011