Stability-indicating HPLC Method for Simultaneous Determination of Montelukast and Fexofenadine Hydrochloride

نویسندگان

  • Mona Pankhaniya
  • Parula Patel
  • J. S. Shah
چکیده

A simple, specific, accurate, and stability-indicating reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of montelukast and fexofenadine hydrochloride, using a Lichrospher(®) 100, RP-18e column and a mobile phase composed of methanol:0.1% o-phosphoric acid (90:10 v/v), pH 6.8. The retention times of montelukast and fexofenadine hydrochloride were found to be 10.16 and 12.03 min, respectively. Linearity was established for montelukast and fexofenadine hydrochloride in the range of 2-10 μg/ml and 24-120 μg/ml, respectively. The percentage recoveries of montelukast and fexofenadine hydrochloride were found to be in the range of 99.09 and 99.81%, respectively. Both the drugs were subjected to acid and base hydrolysis, oxidation, photolytic, and thermal degradation conditions. The degradation products of montelukast and fexofenadine hydrochloride were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of montelukast and fexofenadine hydrochloride in bulk drugs and formulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new stability - indicating RP - HPLC method for the simultaneous determination of fexofenadine hydrochloride and montelukast in combined dosage form

A new stability-indicating RP-HPLC method was developed for the simultaneous determination of fexofenadine hydrochloride and montelukast in combined dosage form, using a Aligent, Zorbax (Make: 150 mmx4.6 mm I.D; particle size 5μm and a mobile phase composed of phospahte buffer (pH 4.0): Acetonitile (60:40 v/v) at a flow rate of 1.0mL/min. The retention times of fexofenadine hydrochloride and mo...

متن کامل

Simultaneous Determination of Montelukast Sodium and Fexofenadine Hydrochloride in Combined Dosage Form by Using RP-HPLC Method

A simple, accurate, economical and reproducible reverse phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the determination of montelukast sodium and fexofenadine hydrochloride in bulk and pharmaceutical formulations. The separation was achieved on a phenomenex C column (150 × 4.6 mm i.d, particle size of 5μ) using a mixture of 0.1M potassium dihydro...

متن کامل

Rapid and Simultaneous Determination of Montelukast, Fexofenadine and Cetirizine Using Partial Least Squares and Artificial Neural Networks Modeling

Simultaneous determination of pharmaceutical compounds and accurate quantitative prediction of them are of great interest in the clinical and laboratory-based investigations.This work has focused on a comprehensive comparison of Partial Least-Squares (PLS-1) and Artificial Neural Networks (ANN) as two powerful types of chemometric methods. For this purpose, montelukast (MONT), fexofenadine ...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2013