The behavior of novel hydrophilic composite bone cements in simulated body fluids.

نویسندگان

  • Luciano F Boesel
  • Maria H V Fernandes
  • Rui L Reis
چکیده

Composite bone cements were formulated with bioactive glass (MgO--SiO(2)--3CaO. P(2)O(5)) as the filler and hydrophilic matrix. The matrix was composed of a starch/cellulose acetate blend (SCA) as the solid component and a mixture of methylmethacrylate/acrylic acid (MMA/AA) as the liquid component. The curing parameters, mechanical properties, and bioactive behavior of these composite cements were determined. The addition of up to 30 wt % of glass improved both compressive modulus and yield strength and kept the maximum curing temperature at the same value presented by a typical acrylic-based commercial formulation. The lack of a strongly bonded interface (because no coupling agent was used) had important effects on the swelling and mechanical properties of the novel bone cements. However, bone cements containing AA did not show a bioactive behavior, because of the deleterious effect of this monomer on the calcium phosphate precipitation on the polymeric surfaces. Formulations without AA were prepared with MMA or 2-hydroxyethyl methacrylate (HEMA) as the liquid component. Only these formulations could form an apatite-like layer on their surface. These systems, therefore, are very promising: They are bioactive, hydrophilic, partially degradable, and present interesting mechanical properties. This combination of properties could facilitate the release of bioactive agents from the cement, allow bone ingrowth in the cement, and induce a press-fitting effect, improving the interfaces with both the prosthesis and the bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and characterization of α-tricalcium phosphate/monocalcium aluminate composite bone cement

Calcium phosphate cements have received much attention in recent decades owing to their biocompatibility, in situ handling, and shaping abilities. However, their low initial mechanical strength is still a major limitation. On the other hand, calcium aluminate cements (CACs) set fast and have a high initial strength and good corrosion resistance in contact with body fluids, making them excellent...

متن کامل

The effect of water uptake on the behaviour of hydrophilic cements in confined environments.

Physiological fluids will be in contact with the implant components from the first moments after a surgery. Therefore, the study of the effect of water on the properties of the bone cements that are part of the arthroplasty procedure is of critical importance to predict the long-term performance of the whole system. In our research group, we have developed a novel concept, the hydrophilic, part...

متن کامل

EFFECT OF ANODIC OXIDATION ON THE CORROSION BEHAVIOR OF NICKEL-TITANIUM SHAPE MEMORY ALLOYS IN SIMULATED BODY FLUIDS (SBF)

The effect of anodic oxidation of a NiTi shape memory alloy in sulfuric acid electrolyte on its surface characteristics was studied. Surface roughness was measured by roughness tester. Surface morphology was studied using optical microscopy (OM) and scanning electron microscopy (SEM). Corrosion behavior was specified by recording Potentiodynamic polarization cur...

متن کامل

Behavior of a Synthesized Bone Cement in Simulated Body Fluid

In this research, effect of soaking time of a new synthesized hydroxyapatite-based bone cement in simulated body fluid (SBF) on the final phase and strength has been studied. The powder section of the cement has been synthesized by using tricalcium phosphate, calcium carbonate and anhydrous dicalcium phosphate. The liquid phase of the cement consists of different concentrations of NaH2PO4.2H2O....

متن کامل

Novel High Capacity Swelling Superabsorbent Composite and Its Potential for Controlled Release of Fertilizers

A hydrophilic macromolecular network is prepared by performing graft copolymerization of poly (sodium acrylate) chains onto salep and silica gel. The reaction parameters affecting the water absorbency of the superabsorbent composite were optimized using Taguchi method. FT-IR spectroscopy and Thermo Gravimetric Analysis (TGA) were used for confirming the s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 70 2  شماره 

صفحات  -

تاریخ انتشار 2004