Analytical evaluation of methods for serum creatine kinase-MB. Electrophoresis, immunoinhibition and solid phase separation.

نویسندگان

  • R H Gadsden
  • C N Papadea
  • J C Cate
چکیده

The purpose of this study was to evaluate immunoassay methods for the measurement of serum cardiac creatine kinase isoenzyme (CK-MB) with respect to sensitivity and specificity. The CK-MB electrophoretic assay (Helena Laboratories) was used as the reference. Two principles of immunoassay were included in the evaluation,--immunoinhibition and solid phase separation. The direct immunoinhibition techniques were from Beckman Instruments (CKMB reagent) and DuPont Medical Products (CKMB). Three solid phase separation techniques were from Abbott Laboratories (IMx CKMB), DuPont (acaPlus MCKMB), and Tosoh Medics Inc. (AIA-Pack CKMB). The electrophoretic method for separation of the CK isoenzymes has good specificity but lacks sensitivity for CK-MB in low concentrations. The immunoinhibition methods lack specificity and correlate poorly with the electrophoresis method and with the solid phase methods. The solid phase separation techniques are highly sensitive and show an excellent correlation with electrophoresis when based on specificity. The solid phase separation methods correlate well with each other.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical and clinical evaluation of creatine kinase MB mass assay by IMx: comparison with MB isoenzyme activity and serum myoglobin for early diagnosis of myocardial infarction.

We analytically and clinically evaluated Abbott's IMx assay for creatine kinase (CK) isoenzyme MB (CK-MB) in serum. Over a 1-year period, the method was more specific but less precise than catalytic isoenzyme measurements by electrophoresis or immunoinhibition. Sera from different individuals without electrophoretic evidence of CK-MB but containing macro CK type 1 (n = 20), mitochondrial CK (n ...

متن کامل

Development and clinical evaluation of a microcentrifugal analyzer method for determining creatine kinase MB isoenzyme.

We have adapted to a microcentrifugal analyzer an immunoinhibition assay for measuring the activity of creatine kinase MB by using an inhibitory antibody for the M monomer. The method actually measures half the MB activity, but results are not multiplied by two because atypical isoenzymes of creatine kinase, including BB, IgG-BB, and the isoenzyme derived from mitochondria, are also detected, i...

متن کامل

Clinical evaluation of an immunoinhibition procedure for creatine kinase-MB.

We have clinically evaluated the Dade "Cardiozyme" immunoinhibition procedure for determination of creatine kinase isoenzyme MB (CK-MG) in 71 patients who were suspected of having had an acute myocardial infarction. Electrophoresis for CK-MB was also carried out. On the basis of diagnostic sensitivity and specificity for myocardial infarction, we found the Dade procedure for CK-MB to be somewha...

متن کامل

Clinical and analytical evaluation of kits for measurement of creatine kinase isoenzyme MB.

We studied the analytical and clinical performance of six methods for creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB): three immunoassays (Behring, Hybritech, and International Immunoassay Labs); one immunoinhibition assay (Roche); one immunoinhibition/column method (Du Pont); and one electrophoretic method (Beckman). Between-day precision for all kits was poor at the upper reference limit. A...

متن کامل

Relative increase in creatine kinase MB isoenzyme during reperfusion after myocardial infarction is method dependent.

We compared relative increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) after reperfusion in myocardial infarction for four popular methods: electrophoresis, immunoinhibition, the "Magic Lite" (Ciba-Corning) system, and the Stratus (Dade). In a method comparison study, we confirmed that all four methods correlated (r greater than 0.95). Electrophoresis demonstrated the greatest scat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 24 2  شماره 

صفحات  -

تاریخ انتشار 1994