Anatomic characterization of human ultra-weak photon emission with a moveable photomultiplier and CCD imaging.

نویسندگان

  • Roeland Van Wijk
  • Masaki Kobayashi
  • Eduard P A Van Wijk
چکیده

Ultra-weak photon emission of a living system has received scientific attention because of its potential for monitoring oxidative metabolism and oxidative damage to tissues. Heretofore, most studies have focused only on the emission from hands. The data regarding emission from other anatomic locations are limited. A previous multi-anatomic site recording of four subjects quantitatively demonstrated that the emission from several corresponding anatomic locations could differ by as much as a factor of 4. The data also suggested a "common" anatomic emission percentage distribution pattern. This information raised the question whether such a typical anatomic percentage emission exists. The objective of the present paper is to systematically replicate the emission from identical anatomic locations to document whether the anatomic percentage distribution pattern is generic. Part 1 includes the recording of ultra-weak photon emission from one sample subject over the torso, head and upper extremities with a highly sensitive charge-coupled device (CCD). Part 2 includes the analysis of that data to select a series of anatomic locations that were subsequently studied with a group of 20 subjects utilizing a highly sensitive, cooled and moveable (in three directions) photomultiplier system. Total sum emission of all recorded anatomic locations per subject fluctuates in this study almost 5-fold between subjects. However, the contribution of each anatomic location to the total emission from each subject was approximately the same percentage for each subject and similar to the sample CCD subject. The deviation of the anatomic percentage contribution for each subject was also established. The study presents evidence that there is a "common" anatomic percentage distribution pattern of ultra-weak photon emission for corresponding locations from each subject.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Ultraweak Photon Emission (UPE) from Cells as a Tool for Pathological Studies

Objective: It is well-known that all living cells emit ultra-weak photon emission (UPE), which is due to byproducts of chemical reactions in cell metabolisms. It has been shown that Reactive Oxygen Species (ROS) in the cells enhances the UPE intensity. The magnitude of such UPE is extremely weak (i.e. a few to 103 photons/ (sec.cm2)), and the detection of such ultra-weak signals is hardly possi...

متن کامل

Towards the two-dimensional imaging of spontaneous ultra-weak photon emission from microbial, plant and animal cells

Two-dimensional imaging of spontaneous ultra-weak photon emission was measured in the yeast cells, Arabidopsis plant and the human hand using highly sensitive charge coupled device (CCD) camera. For the first time, the detail analysis of measuring parameters such as accumulation time and binning is provided with the aim to achieve two-dimensional images of spontaneous ultra-weak photon emission...

متن کامل

Spontaneous Ultra-Weak Photon Emission from Human Hands Is Time Dependent

Ultra-weak photon emission in the visible range was measured on palm and dorsal side of left and right hand by means of a low noise photomultiplier system. To study the dynamics of this photon emission in a 24 h period photon emission was recorded in 2 h intervals in 5 experiments, utilizing strict protocols for dark adaptation and recording of subjects. Fluctuations in photon emission in the c...

متن کامل

Anatomic characterization of human ultra-weak photon emission in practitioners of transcendental meditation(TM) and control subjects.

BACKGROUND Research on human ultra-weak photon emission (UPE, biophoton emission) has raised the question whether a typical human emission anatomic percentage distribution pattern exists in addition to individual subject overall anatomic summation intensity differences. The lowest UPE intensities were observed in two subjects who regularly meditate. Spectral analysis of human UPE has suggested ...

متن کامل

Linoleic Acid-Induced Ultra-Weak Photon Emission from Chlamydomonas reinhardtii as a Tool for Monitoring of Lipid Peroxidation in the Cell Membranes

Reactive oxygen species formed as a response to various abiotic and biotic stresses cause an oxidative damage of cellular component such are lipids, proteins and nucleic acids. Lipid peroxidation is considered as one of the major processes responsible for the oxidative damage of the polyunsaturated fatty acid in the cell membranes. Various methods such as a loss of polyunsaturated fatty acids, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of photochemistry and photobiology. B, Biology

دوره 83 1  شماره 

صفحات  -

تاریخ انتشار 2006