Transcutaneous oxygen and carbon dioxide monitoring in intensive care.
نویسندگان
چکیده
Transcutaneous oxygen (TcPo2) and carbon dioxide (TcPco2) tensions were compared with arterial values in 23 children aged 4 months to 14 years, all requiring some form of respiratory support, but not in shock. Electrodes were placed on the upper chest and were heated to 45 degrees C. For TcPo2 and arterial oxygen (Pao2) a tight linear correlation over the range 6 to 14 kPa was found. Arterial carbon dioxide (Paco2) ranged between 2.63 and 6.8 kPa, and over this range a linear regression adequately described the relation of TcPco2 to Paco2. No effects of age were found for the relation between TcPo2 and Pao2. Over a four hour period, the mean ratio TcPo2/Pao2 rose significantly from 0.96 to 1.04, while the mean ratio of TcPco2/Paco2 fell from 1.65 to 1.62. Five children developed superficial burns which were still present at 48 hours. In children who require respiratory support but are not in shock, TcPo2 and TcPco2 bear a constant and predictable relation to Pao2 and Paco2, and can predict arterial values within clinically acceptable tolerances.
منابع مشابه
End-tidal carbon dioxide and transcutaneous carbon dioxide monitoring during neonatal transport
Abbreviations: CO2, Carbon dioxide; PaCO2, Arterial partial pressure of carbon dioxide; PtcCO2, Transcutaneous partial pressure of carbon dioxide; PetCO2, End-tidal partial pressure of carbon dioxide; NETS, Newborn Emergency Transport Service (Victoria); NICU, Neonatal Intensive Care Unit; PaO2/PAO2 ratio, alveolar-arterial ratio. ADC-FNN Online First, published on April 29, 2005 as 10.1136/adc...
متن کاملUse of a Combined SpO2/PtcCO2 Sensor in the Delivery Room
Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recen...
متن کاملA Survey of Transcutaneous Blood Gas Monitoring Among European Neonatal Intensive Care Units
Background PCO2 and PO2 are important monitoring parameters in neonatal intensive care units (NICU). Compared to conventional blood gas measurements that cause significant blood loss in preterms, transcutaneous (tc) measurements allow continuous, non-invasive monitoring of blood gas levels. The aim of the study was to survey the usage and opinions among German speaking NICUs concerning tc blood...
متن کاملA Survey of Transcutaneous Blood Gas Monitoring Among European Neonatal Intensive Care Units
Background PCO2 and PO2 are important monitoring parameters in neonatal intensive care units (NICU). Compared to conventional blood gas measurements that cause significant blood loss in preterms, transcutaneous (tc) measurements allow continuous, non-invasive monitoring of blood gas levels. The aim of the study was to survey the usage and opinions among German speaking NICUs concerning tc blood...
متن کاملConcordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory service setting
Non-invasive monitoring of arterial oxygen using percutaneous pulse oximetry is well established. Although some studies show a good correlation of transcutaneous end-tidal carbon dioxide partial pressure (PetCO2) with arterial carbon dioxide partial pressure (PaCO2), they were performed in research settings and involved restricted populations such as paediatric, accident and emergency, or inten...
متن کاملThe Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP)
BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood
دوره 60 12 شماره
صفحات -
تاریخ انتشار 1985