Maintaining optimal oxygen saturation in premature infants.
نویسندگان
چکیده
INTRODUCTION Advances in technology have resulted in increasing survival rates for premature infants. Oxygen therapy is commonly used in neonatal units as part of respiratory support. The number of premature infants in our institution surviving with severe (stage ≥3) retinopathy of prematurity (ROP) prompted a review of oxygen therapy as a contributing factor. Prolonged exposure to high concentrations of oxygen may cause irreversible damage to the eyes of very-low-birth-weight preterm infants and is a potential cause of blindness. OBJECTIVE We developed strategies to reduce incidence of severe ROP requiring laser surgery in premature infants. METHODS We studied 37 preterm infants who were born at a gestational age of <32 weeks, with a birth weight of <1500 g, receiving supplemental oxygen, and had been admitted to our neonatal intensive care unit. Infants received oxygen via mechanical ventilator, nasal continuous positive airway pressure (CPAP), or intranasal (I/N) and titration of oxygen was based on each infant's measured oxygen saturation (Spo(2)). For each infant, we monitored the Spo(2) trend, Spo(2) alarm limit, and the percentage of time that the alarm limit was set incorrectly. We implemented a Spo(2) targeting protocol and developed an algorithm for titrating fraction of inspired oxygen (Fio(2)). RESULTS After phase 1 of implementation, the percentage of time that Spo(2) readings were >95% was reduced to between 20% and 50%. However, our findings raised concern regarding the wide fluctuation of Spo(2) readings because of inconsistency in Fio(2) titration, which can contribute to deviation from the optimal target range. Accordingly, we developed an algorithm for titrating Fio(2) aimed at maintaining each infant's Spo(2) within the optimal target range. After phase 2 of implementation, the percentage of Spo(2) readings >95% was markedly reduced to between 0% and 15%. The incidence of infants with severe ROP requiring laser surgery decreased from 5 to 1. CONCLUSIONS A change in clinical practice aimed at maintaining oxygen within the target range to avoid a high Spo(2) was associated with a significant decrease in the incidence of both severe ROP and the need for laser surgery, thus reducing hospital costs and length of hospital stays for premature infants.
منابع مشابه
Effect of multisensory stimulation on oxygen saturation in premature infants during eye examination
Background: Eye examination for screening of Retinopathy of Prematurity (ROP), as a painful procedure, causes physiological changes in premature infants. Multisensory stimulation is a non-pharmacological analgesic method which affects physiological measures during painful procedures. Aim: To determine the effect of multisensory stimulation on oxygen saturation in premature infants during eye ex...
متن کاملThe effect of breast milk odor on concentration percentage of oxygen saturation and respiratory rate in premature infants
Background: establishing a regular respiratory condition in the infants is one of the basic considerations in NICU. Newborns show noticeable breath alterations in response to even low concentrations of some fragrance. Aim: determining the effect of breast milk odor on oxygen saturation and respiratory rate in premature infants. Methods: In this four-group randomized clinical trial, 180 prematu...
متن کاملEffect of the Artificial Night with Facilitated Tucking and Artificial Night Alone on the Physiological Indices of Premature Infants
Background: Preterm birth and admission to neonatal intensive care unit as stressors can cause physiologicalinstability that may lead to prolong hospitalization and mortality. This study aimed to determine the effect of artificialnights and facilitated tucking on the physiological indices of premature infants.Methods: This randomized clinical trial was conducted on 60 preterm ...
متن کاملOptimal oxygen saturation in premature infants
There is a delicate balance between too little and too much supplemental oxygen exposure in premature infants. Since underuse and overuse of supplemental oxygen can harm premature infants, oxygen saturation levels must be monitored and kept at less than 95% to prevent reactive oxygen species-related diseases, such as retinopathy of prematurity and bronchopulmonary dysplasia. At the same time, d...
متن کاملComparison of the Effects of Supine and Prone Positions on Oxygen Saturation and Vital Signs in Premature Infants: A Crossover Clinical Trial
Background: Positioning of premature newborns significantly affects their health status. However, the most suitable position remains controversial. The current study aimed to compare the effect of supine and prone positions on oxygen saturation and vital signs in premature newborns. Methods: In this crossover clinical trial, a total of 22 new...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Permanente journal
دوره 15 1 شماره
صفحات -
تاریخ انتشار 2011