Suture strength and angle of load application in a suture anchor eyelet.

نویسندگان

  • Mark Deakin
  • David Stubbs
  • Warwick Bruce
  • Jerome Goldberg
  • Ronald M Gillies
  • William R Walsh
چکیده

PURPOSE To assess the effect of suture material, anchor orientation, and anchor eyelet design on the static loading properties of suture anchors. TYPE OF STUDY Biomechanical bench study. METHODS Two metallic suture anchors, Mitek GII (Mitek, Westwood, MA) and Corkscrew (Arthrex, Naples, FL) and a bioabsorbable anchor (Biocorkscrew; Arthrex) were tested with single strand of No. 2 Ethibond (Ethicon, Norderstedt, Germany) or No. 2 FiberWire (Arthrex) suture. Suture pull angle was varied through 0 degrees, 45 degrees, and 90 degrees with the anchor rotation angle in either a sagittal or coronal plane. Constructs were tested to failure using an MTS 858 Bionix testing machine (Material Testing Systems, Eden Prairie, MN). Peak loads, stiffness, energy to peak load, and failure modes were determined for all samples. RESULTS FiberWire showed superior static mechanical properties when compared with single-strand Ethibond over all testing conditions (P < .05). Suture pull angle had a significant effect on load to failure with both metallic anchors but not on the bioabsorbable anchor (P < .05). CONCLUSIONS Suture pull angle and anchor rotation angle play an important role in the failure load of suture when placed in an eyelet. The polyaxial nature of the Biocorkscrew eyelet allows for increased degrees of freedom but introduces failure of the suture eyelet as a new failure mode. CLINICAL RELEVANCE The loading direction and placement of the suture anchor plays a role in the performance of the suture anchor-suture complex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical testing of absorbable suture anchors.

PURPOSE Absorbable suture anchors offer great advantages but are made of mechanically weak material. The weakest link in the fixation of soft tissue to bone may therefore be the anchor itself. In this study, several commercially available anchors were mechanically tested in vitro. TYPE OF STUDY Biomechanical bench study. METHODS Twelve absorbable suture anchor models were implanted into an ...

متن کامل

Failure mode of suture anchors as a function of insertion depth.

BACKGROUND Surgeons can control not only the angle but also the depth of suture anchor placement during arthroscopic rotator cuff repair, although the tendency may be to place suture anchors on the deep side to avoid damage from prominent anchor eyelets. However, little information is available regarding possible effects of suture anchor depth on construct failure mechanisms. HYPOTHESIS Ancho...

متن کامل

Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone

OBJECTIVES This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). METHODS Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cad...

متن کامل

Frontal Plane Humeral Elevation Effects on the Pullout Strength of Suture Anchors Used in Rotator Cuff Repair

Frontal plane humeral elevation effects on the pullout strength of suture anchors used in rotator cuff repair The rotator cuff offers the stabilizing forces necessary for fine arm movement. The most common injury to the rotator cuff is the partial or full thickness tear of the supraspinatus tendon, which attaches the humerus to the scapula on the superior side, due to an acute or chronic injury...

متن کامل

Intraoperative arthroscopic suture anchor reloading.

The success of an arthroscopic procedure depends considerably on the successful and secure tying of arthroscopic knots, which reapproximate and stabilize avulsed or torn soft tissues to their original bed. Failure to perform appropriate knot tying may jeopardize the success of the operation. We describe a simple and reliable technique for intraoperative arthroscopic replacement of the suture th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 21 12  شماره 

صفحات  -

تاریخ انتشار 2005