Bacterial transmission from contact lenses to porcine corneas: an ex vivo study.

نویسندگان

  • Pit B J Vermeltfoort
  • Theo G van Kooten
  • Gerda M Bruinsma
  • Anneke M M Hooymans
  • Henny C van der Mei
  • Henk J Busscher
چکیده

PURPOSE To quantify the transmission to ex vivo porcine eyes of Staphylococcus aureus 835 and Pseudomonas aeruginosa 3 from three types of contact lenses-one daily wear and two extended wear-differing in hydrophobicity and roughness. METHODS One daily wear lens (etafilcon) and two extended-wear lenses (one lotrafilcon A and one balafilcon A) were inoculated in a bacterial suspension for 30 minutes and then placed on ex vivo porcine eyes. After 16 hours of contact between lens and eye, confocal laser scanning microscopy was used to determine the number of bacteria on the lens and cornea for the calculation of transmission percentages. RESULTS Transmission percentages were significantly different for both bacterial strains from an etafilcon A lens and balafilcon A lens (P = 0.006 and 0.04, respectively). Percentages varied from 51% to 68% for the hydrophobic P. aeruginosa and from 54% to 82% for the hydrophilic S. aureus strain, depending on the contact lens involved. Both strains were transferred the least from the most hydrophilic and roughest lens made of lotrafilcon A, although the difference was only statistically significant for S. aureus. CONCLUSIONS Bacterial transmission to the porcine cornea differed in the various types of contact lenses and was least in the hydrophilic and rough lens type.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Second harmonic generation imaging of corneal stroma after infection by Pseudomonas aeruginosa

Pseudomonas aeruginosa is a pathogenic gram-negative organism that has the ability to cause blinding corneal infections following trauma and during contact lens wear. In this study, we investigated the directional movement and orientation of an invasive corneal isolate of P. aeruginosa in the corneal stroma during infection of ex vivo and in vivo rabbit corneas using multiphoton fluorescence an...

متن کامل

In vitro and in vivo evaluation of novel ciprofloxacin-releasing silicone hydrogel contact lenses.

PURPOSE The purpose of this study was to evaluate ciprofloxacin-releasing silicone hydrogel contact lens materials in vitro and in vivo for the treatment of microbial keratitis. METHODS Model silicone hydrogel contact lens materials were manufactured using a molecular imprinting technique to modify ciprofloxacin release kinetics. Various contact lens properties, including light transmission a...

متن کامل

Biocompatibility of antimicrobial melimine lenses: rabbit and human studies.

PURPOSE Covalent immobilization of antimicrobial peptide melimine onto contact lenses can produce broad-spectrum antimicrobial lenses. The purpose of this study was to investigate the performance of melimine-coated contact lenses in an animal model and human clinical trial. METHODS Melimine was covalently attached onto the surface of contact lenses via EDC (1-ethyl-3-[3-dimethylaminopropyl] c...

متن کامل

Extended Release of an Anti–Heparan Sulfate Peptide From a Contact Lens Suppresses Corneal Herpes Simplex Virus-1 Infection

PURPOSE To prolong the release of a heparan sulfate binding peptide, G2-C, using a commercially available contact lens as a delivery vehicle and to demonstrate the ability of the released peptide to block herpes simplex virus-1 (HSV-1) infection using in vitro, ex vivo, and in vivo models of corneal HSV-1 infection. METHODS Commercially available contact lenses were immersed in peptide soluti...

متن کامل

Effects of soft contacts of differing thickness on corneal wound healing in rabbits.

This study was undertaken to determine the effects of thin (60 microns) and thick (240 microns) soft contact lenses of equal water content (70%) and power on nonlesioned and lesioned rabbit corneas. In one group of animals, corneas were not lesioned. Thin lenses were placed on left corneas and thick lenses on right corneas. In a second group, lesions were made in both corneas. Left corneas were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2005