Interrupted coalescent nitinol clip versus continuous suture coronary anastomosis: a comparative endothelial function study.
نویسندگان
چکیده
BACKGROUND A new penetrating stapled anastomotic system using nitinol microclips (Coalescent Surgical U-Clip) has been developed to facilitate the construction of compliant interrupted sutures for minimally invasive and robotic surgery as well as for conventional procedures. The purpose of this study was to determine the effect of nitinol U-Clips used for coronary anastomosis in the development of endothelial dysfunction, compared with conventional running sutures. METHODS In a porcine model, both internal thoracic arteries were harvested, and the heart was removed. In a Krebs solution, 2 anastomoses were realized ex vivo between internal thoracic arteries and the left anterior descending artery. One was carried out with 12 Coalescent microclips, and the other used conventional running 7-0 polypropylene suture material (Prolene). Coronary rings on the anastomotic sites were then placed in organ chambers filled with oxygenated Krebs solution. Vascular reactivity studies were performed in standard organ chamber experiments. After the contraction of the coronary arteries in response to prostaglandin F2alpha, the endothelium-dependent relaxation response to bradykinin was studied. The other coronary arteries served as controls. RESULTS There was no statistically significant difference among the groups (P >.05) in the amplitude of the contraction response to KCl and prostaglandin F2alpha. There were no statistically significant differences in endothelium-dependent relaxation response to bradykinin between the nitinol microclip group and controls, between the suture group and controls, and between the nitinol microclip and suture groups. CONCLUSIONS Coalescent nitinol U-Clips used as anastomotic devices do not induce an endothelial dysfunction and allow a compliant anastomosis under satisfactory conditions.
منابع مشابه
U-clip anastomoses in coronary artery bypass grafting: initial clinical experience.
BACKGROUND Recent studies suggest that the U-Clip interrupted coronary artery anastomosis is superior to continuous suture. However, clinical experience with this device is limited. AIM To evaluate our initial clinical experience with the U-Clip technology. METHODS Outcomes of 59 patients undergoing isolated coronary artery bypass grafting (CABG) using U-Clips (UCs) were compared to outcome...
متن کاملContinuous versus interrupted suture technique in microvascular anastomosis in rats.
PURPOSE To compare the continuous and interrupted suture technique on femoral artery on rats after vessel repair and 14 days after. METHODS Twenty rats were operated randomly divided into two group matched according to the suture technique used: interrupted or continuous. We performed a femoral anastomosis on the right femoral artery. We analyzed weight, arterial caliber, anastomosis time and...
متن کاملClinical and six-month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device: a multicenter prospective clinical trial.
OBJECTIVES To evaluate the safety and effectiveness of a self-closing surgical clip with an interrupted technique in left internal thoracic artery to left anterior descending artery bypass grafting. METHODS Eighty-two patients were enrolled and treated (February 2000 through August 2001) in a prospective, nonrandomized, multicenter trial. Left internal thoracic artery to left anterior descend...
متن کاملClinical and pathological assessment of different suture techniques for microvascular anastomosis in rat femoral artery
This study examined the clinical and pathological features after a microvascular anastomosis of a rat femoral artery using four different suture techniques. Sixty Sprage-Dawely rats were divided randomly into 4 groups. Fifteen bisected arteries (one from each animal) in Group I, II, III and IV were sutured with the simple interrupted suture, continuous suture, sleeve suture and cuff suture, res...
متن کاملUse of the U-clip for microvascular anastomosis.
Microvascular anastomosis is a demanding skill requiring technical excellence and a thorough knowledge of anatomy and physiology. Every suture placed in a microvascular anastomosis should be considered critical as each has the potential to compromise the delicate reconstruction. As such, any device that can facilitate microvascular suture placement deserves thorough evaluation. The U-clip (Coal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The heart surgery forum
دوره 6 2 شماره
صفحات -
تاریخ انتشار 2003