Analysis of N-nitrosamines in water by isotope dilution gas chromatography-electron ionisation tandem mass spectrometry.

نویسندگان

  • James A McDonald
  • Nick B Harden
  • Long D Nghiem
  • Stuart J Khan
چکیده

A method has been developed for the determination of eight N-nitrosamines in drinking water and treated municipal effluent. The method uses solid phase extraction (SPE), gas chromatography (GC) and analysis by tandem mass spectrometry (MS-MS) with electron ionization (EI). The target compounds are N-nitrosodimethylamine (NDMA), N-nitrosomethyethylamine (NMEA), N-nitrosodiethylamine NDEA), N-nitrosodipropylamine (NDPA), N-nitrosodi-n-butylamine (NDBuA), N-nitrosodiphenylamine (NDPhA), N-nitrosopyrrolidine (NPyr), N-nitrosopiperidine (NPip), N-nitrosomorpholine (NMorph). The use of direct isotope analogues for isotope dilution analysis of all analytes ensures accurate quantification, accounting for analytical variabilities that may occur during sample processing, extraction and instrumental analysis. Method detection levels (MDLs) were determined to describe analyte concentrations sufficient to provide a signal with 99% certainty of detection. The established MDLs for all analytes were 0.4-4 ng L(-1) in a variety of aqueous matrices. Sample matrices were observed to have only a minor impact on MDLs and the method validation confirmed satisfactory method stability over intra-day and inter-day analyses of tap water and tertiary treated effluent samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

GC/CI-MS/MS method for the identification and quantification of volatile N-nitrosamines in meat products.

A sensitive and selective method was developed and validated for the determination of nine N-nitrosamines in meat products. The N-nitrosamines were extracted with NaOH/methanol, partitioned into dichloromethane on a ChemElut column and cleaned-up by solid-phase extraction. All samples were spiked with (2)H isotope-labelled N-nitrosamine internal standard prior to extraction. After purification ...

متن کامل

Determination of perchlorate in infant formula by isotope dilution ion chromatography/tandem mass spectrometry

A sensitive and selective isotope dilution ion chromatography/tandem mass spectrometry (ID IC-MS/MS) method was developed and validated for the determination of perchlorate in infant formula. The perchlorate was extracted from infant formula by using 20 ml of methanol and 5 ml of 1% acetic acid. All samples were spiked with (18)O(4) isotope-labelled perchlorate internal standard prior to extrac...

متن کامل

Quantitation of urinary volatile nitrosamines from exposure to tobacco smoke.

A sensitive and selective method was developed and validated to detect six volatile nitrosamines (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosopiperidine, N-nitrosopyrrolidine and N-nitrosomorpholine) in human urine. This method uses a liquid-liquid extraction cartridge followed by analysis with gas chromatography-tandem mass spectrometry (GC-MS-MS) and qua...

متن کامل

Simultaneous determination of estrogenic and androgenic hormones in water by isotope dilution gas chromatography-tandem mass spectrometry.

A rapid gas chromatography-tandem mass spectrometry (GC-MS/MS) analytical method was developed for the simultaneous analysis of 7 estrogenic hormones (17α-estradiol, 17β-estradiol, estrone, mestranol, 17α-ethynylestradiol, levonorgestrel, estriol) and 5 androgenic hormones (testosterone, androsterone, etiocholanolone, dihydrotestosterone, androstenedione) in aqueous matrices. This method is uni...

متن کامل

Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards.

A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of (81)Br-labelled PBDEs for isotope dilution analysis and the measurement of (79)Br/(81)Br i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 99  شماره 

صفحات  -

تاریخ انتشار 2012