Low rate of and rapid attention to inappropriate ICD shocks with remote device and rhythm monitoring: a qualitative study
نویسندگان
چکیده
OBJECTIVES Inappropriate shocks are unpleasant and painful. We hypothesise that remote monitoring and careful attention to known and incident atrial fibrillation (AF) can reduce inappropriate shocks to a very low level in clinical praxis. METHODS Altogether 259 patients with implantable cardioverter defibrillator implanted for secondary (S, n=113) and primary (P, n=146) prevention were followed via remote monitoring. At implant, 42S (37%) and 54P (37%) patients had known AF. RESULTS Inappropriate shocks, all but five due to AF, occurred in 7S (6.2%) and 11P (7.5%), and there were only inappropriate shocks in 5/7S and in 8/11P. They occurred in four of 42S (9.5%) with and in three of 71S (4.2%) without known AF, and in seven of 54P (13%) with and in four of 92P (4.3%) without known AF. The median time from shock to action was 5 and 1 day, respectively. Actions were medication with amiodarone, β blockers, β blockers+amiodarone or β blockers+digoxin (n=5), β blockers+insertion of an atrial lead (n=1), replacement of a fractured lead (n=2), reprogramming in combination with β blockers, digoxin or amiodarone (n=4), reprogramming (n=2) and none (n=4). After action, four further inappropriate shocks occurred during more than 2 years of follow-up, all due to AF. CONCLUSIONS Inappropriate shocks occurred at a low rate and most often because of AF known at implant. Remote monitoring enabled rapid action, after which few inappropriate shocks occurred over more than 2 years. Attention to known and incident AF was the most important action to reduce inappropriate shocks.
منابع مشابه
کاربرد مدلهای نیمهپارامتری بقا در ارزیابی عوامل خطر وابسته به زمان بر نرخ شوکهای واردشده به بیماران قلبی
Background: One of the treatments in patients with dangerous diseases particularly heart failure, is Implantable Cardioverter Defibrillator (ICD) that is used to prevent sudden cardiac death. Regarding to the superiority of ICD rather than medical treatment, the purpose of this study is the assessment of time-dependent effective factors on the rates of entered shocks to patients with ICD. ...
متن کاملThe benefits of remote monitoring in long-term care for patients with implantable cardioverter-defibrillators.
OBJECTIVE The increasing number of patients with implantable cardiac devices raises the need for more efficient outpatient follow-up care. Due to technological progress in communication and transmission systems and in the implantable devices themselves, telemonitoring can be widely used as an important part of care for patients and devices. Our objective was to evaluate the benefits of continuo...
متن کاملتعیین عوامل مرتبط با دریافت شوکهای بهجا و نابهجای ICD در بیماران قلبی
Background and Aim: The QRS duration is a strong predictor of mortality, particularly in heart failure patients. However, studies on the usefulness of QRS duration, as a predictor of ventricular arrhythmic events in ICD patients, have proved to be contradictory. Since in patients with implantable cardioverter defibrillator (ICD), all of the malignant ventricular arrhythmias are recorded and tr...
متن کاملFrequent Home Monitoring of ICD Is Effective to Prevent Inappropriate Defibrillator Shock Delivery
Recently, in the context of telemedicine, telemonitoring services are gaining attention. They are offered, for example, to patients with implantable cardioverter defibrillators (ICDs). A major problem associated with ICD therapy is the occurrence of inappropriate shocks which impair patients' quality of life and may also be arrhythmogenic. The telemonitoring can provide a valid support to inten...
متن کاملContributions of remote monitoring to the follow-up of implantable cardioverter–defibrillator leads under advisory
AIMS Automatic daily transmission of data from implantable cardioverter-defibrillators (ICDs) enables the remote monitoring of device status and leads function. We report on a 2-year experience with remote monitoring in 40 recipients of high-voltage ICD leads, prone to fracture and under advisory since October 2007. METHODS AND RESULTS The ICDs were remotely monitored as well as systematicall...
متن کامل