The position of the tibial component affecting the postoperative mechanical axis in total knee arthroplasty.

نویسندگان

  • Dae Kyung Bae
  • Sang Jun Song
  • Kyoung Ho Yoon
  • Seung Mok Shin
چکیده

The purpose is to identify whether the position of the tibial component in relation to the anatomical axis affects the postoperative mechanical axis in total knee arthroplasty for Korean patients. Preoperatively, 30 patients with varus deformity lesser than 10° were classified as group A, and 30 patients greater than 10° were classified as group B. Postoperatively, the distance between the midline of the tibial stem and anatomical axis (medial offset) was measured. The medial offsets were 2.5±1.9 mm in group A and 3.9±2.7 mm in group B (P=.021). The postoperative mechanical axes were varus 1.3±1.2° in group A and varus 2.5±2.0° in group B (P=.004). We think that the medial position of tibial component in relation to the anatomical axis affects the measurement of postoperative mechanical axis in total knee arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases

Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Tibial component rotation in total knee arthroplasty

BACKGROUND Both the range of motion (ROM) technique and the tibial tubercle landmark (TTL) technique are frequently used to align the tibial component into proper rotational position during total knee arthroplasty (TKA). The aim of the study was to assess the intra-operative differences in tibial rotation position during computer-navigated primary TKA using either the TTL or ROM techniques. The...

متن کامل

Acute Primary Total Knee Arthroplasty for Proximal Tibial Fractures in Elderly

Background: Proximal tibial fractures in elderly patients with osteoporosis or knee osteoarthritis (OA) are challengingcases. In the current study, we present our experience with uncommon acute primary total knee arthroplasty (PTKA)in this patient population.Methods: PTKAs were performed following proximal tibial fractures in 30 consecutive patients over 60 years of agewith osteoporosis or knee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 25 7  شماره 

صفحات  -

تاریخ انتشار 2010