Optical coherence tomography versus intravascular ultrasound to evaluate stent implantation in patients with calcific coronary artery disease
نویسندگان
چکیده
AIMS Stent underexpansion and malapposition are associated with adverse outcomes following percutaneous coronary intervention, but detection and treatment can be challenging in the presence of extensive coronary artery calcification. Frequency domain optical coherence tomography (FD-OCT) is a novel intravascular imaging technique with greater spatial resolution than intravascular ultrasound (IVUS) but its role in the presence of extensive coronary calcification remains unclear. We sought to determine the utility of FD-OCT compared to IVUS imaging to guide percutaneous coronary intervention in patients with severe calcific coronary artery disease. METHODS 18 matched IVUS and FD-OCT examinations were evaluated following coronary stent implantation in 12 patients (10 male; mean age 70±7 years) undergoing rotational atherectomy for symptomatic calcific coronary artery disease. RESULTS In-stent luminal areas were smaller (minimum in-stent area 6.77±2.18 vs 7.19±2.62 mm(2), p<0.05), while reference lumen dimensions were similar with FD-OCT compared with IVUS. Stent malapposition was detected in all patients by FD-OCT and in 10 patients by IVUS. The extent of stent malapposition detected was greater (20% vs 6%, p<0.001) with FD-OCT compared to IVUS. Postdilation increased the in-stent luminal area (minimum in-stent area: 8.15±1.90 vs 7.30±1.62 mm(2), p<0.05) and reduced the extent of stent malapposition (19% vs 34%, p<0.005) when assessed by FD-OCT, but not IVUS. CONCLUSIONS Acute stent malapposition occurs frequently in patients with calcific coronary disease undergoing rotational atherectomy and stent implantation. In the presence of extensive coronary artery calcification, FD-OCT affords enhanced stent visualisation and detection of malapposition, facilitating improved postdilation stent apposition and minimal luminal areas. TRIAL REGISTRATION NUMBER NCT02065102.
منابع مشابه
Impact of frequency-domain optical coherence tomography guidance for optimal coronary stent implantation in comparison with intravascular ultrasound guidance.
BACKGROUND Frequency-domain optical coherence tomography (FD-OCT) is a novel, high resolution intravascular imaging modality. Intravascular ultrasound (IVUS) is a widely used conventional imaging modality for achieving optimal stent deployment. The aim of this study was to evaluate the impact of FD-OCT guidance for coronary stent implantation compared with IVUS guidance. METHODS AND RESULTS A...
متن کاملStent Evaluation with Optical Coherence Tomography
Optical coherence tomography (OCT) has been recently applied to investigate coronary artery disease in interventional cardiology. Compared to intravascular ultrasound, OCT is able to visualize various vascular structures more clearly with higher resolution. Several validation studies have shown that OCT is more accurate in evaluating neointimal tissue after coronary stent implantation than intr...
متن کاملThe Role of Optical Coherence Tomography in Coronary Intervention
Optical coherence tomography (OCT) is an optical analog of intravascular ultrasound (IVUS) that can be used to examine the coronary arteries and has 10-fold higher resolution than IVUS. Based on polarization properties, OCT can differentiate tissue characteristics (fibrous, calcified, or lipid-rich plaque) and identify thin-cap fibroatheroma. Because of the strong attenuation of light by blood,...
متن کاملPercutaneous Coronary Intervention: Safety of Methotrexate and Its Possible Benefits on Restenosis After Bare-Metal Stent Deployment
BACKGROUND Percutaneous coronary intervention (PCI) revolutionized treatment of coronary artery disease. Drug-eluting stents are effective and safe but their cost is high, especially for some countries. The primary objective was to evaluate the safety of methotrexate (MTX) in patients who underwent PCI and the secondary goal was to evaluate the possibility that MTX has an impact on restenosis. ...
متن کاملPatient profile and periprocedural outcomes of bioresorbable vascular scaffold implantation in comparison with drug-eluting and bare-metal stent implantation. Experience from ORPKI Polish National Registry 2014–2015
INTRODUCTION There are limited data on the comparison of bioresorbable vascular scaffold (BVS) and drug-eluting stent (DES)/bare-metal stent (BMS) implantation in an unselected population of patients with coronary artery disease. AIM To compare the periprocedural outcomes and patient profile of BVS and DES/BMS implantation in an all-comer population from the ORPKI Polish National Registry. ...
متن کامل