Detection of uranium in industrial and mines samples by microwave plasma torch mass spectrometry.

نویسندگان

  • Yi Li
  • Meiling Yang
  • Rong Sun
  • Tao Zhong
  • Huanwen Chen
چکیده

Microwave plasma torch (MPT), traditionally used as the light source for atomic emission spectrophotometry, has been employed as the ambient ionization source for sensitive detection of uranium in various ground water samples with widely available ion trap mass spectrometer. In the full-scan mass spectra obtained in the negative ion detection mode, uranium signal was featured by the uranyl nitrate complexes (e.g. [UO2 (NO3 )3 ](-) ), which yielded characteristic fragments in the tandem mass spectrometry experiments, allowing confident detection of trace uranium in water samples without sample pretreatment. Under the optimal experimental conditions, the calibration curves were linearly responded within the concentration levels ranged in 10-1000 µg·l(-1) , with the limit of detection (LOD) of 31.03 ng·l(-1) . The relative standard deviations (RSD) values were 2.1-5.8% for the given samples at 100 µg·l(-1) . The newly established method has been applied to direct detection of uranium in practical mine water samples, providing reasonable recoveries 90.94-112.36% for all the samples tested. The analysis of a single sample was completed within 30 s, showing a promising potential of the method for sensitive detection of trace uranium with improved throughput.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Determination of Ingredients in Solid Pharmaceuticals by Microwave-Enhanced In-Source Decay of Microwave Plasma Torch Mass Spectrometry

Rapid qualitative and quantitative analysis of solid samples (e.g., pharmaceutical preparations) by using a small and low-resolution mass spectrometer without MS/MS function is still a challenge in ambient pressure ionization mass spectrometric analysis. Herein, a practically efficient method termed microwave-enhanced in-source decay (MEISD) using microwave plasma torch desorption ionization co...

متن کامل

Some Rare Earth Elements Analysis by Microwave Plasma Torch Coupled with the Linear Ion Trap Mass Spectrometry

A sensitive mass spectrometric analysis method based on the microwave plasma technique is developed for the fast detection of trace rare earth elements (REEs) in aqueous solution. The plasma was produced from a microwave plasma torch (MPT) under atmospheric pressure and was used as ambient ion source of a linear ion trap mass spectrometer (LTQ). Water samples were directly pneumatically nebuliz...

متن کامل

Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of mass spectrometry : JMS

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2016