Changes in the polymorphonuclear leukocyte function of blood samples induced by storage time, temperature and agitation.
نویسندگان
چکیده
We have investigated changes in polymorphonuclear leukocyte (PMN) functions of blood samples caused by such typical elements of laboratory handling as storage time, temperature and agitation. The blood of five healthy subjects was stored upright in test tubes at 4, 22 and 37 degrees C over periods of 20 min, one, two, six and 24 h. Controlled agitation was performed on a shaker. The following PMN functional parameters were measured: the white blood cell count (WBC), migration, elastase (EL) release, reactive oxygen species (ROS) production and lipid peroxidation. Migration was determined in a whole-blood membrane filter assay; ROS production by latex-stimulated, luminol-enhanced chemiluminescence (CL) in a whole-blood assay; EL as EL alpha 1-antitrypsin complex; and lipid peroxidation by malondialdehyde (MDA) generation. The reactions after handling were compared with the values measured immediately after blood withdrawal which served as reference values of 'genuine' PMN reactivity. The outstanding result was the marked scatter between the individual reactions. Overall, the proportion of migrating PMNs in the blood total decreased, while CL, correlating positively with MDA, increased with the time of storage. EL increased considerably in some of the samples. Agitation raised CL and MDA. The effect of temperature was apparent only after 24 h at 37 degrees C. There was evidence that inhomogeneities in the blood samples were another interfering factor, since resuspension of sedimented blood after storage can be incomplete. In order to obtain reliable results from PMN functional tests, whole-blood assays and processing of blood samples within 20 min after blood withdrawal are recommended.
منابع مشابه
Evaluation of microRNAs; mir223, mir222 and mir92a levels in the Platelet-derived microparticles in the Platelet concentrates produced by Platelet Rich Plasma method during storage
Abstract Background and Objectives Platelets release microparticles containing cellular components, including microRNAs, during storage. Assessment of these microRNAs is one of the markers for evaluation of platelet storage lesions. The aim of the present study was to evaluate the level of changes in the expression of mir-223, mir-92a and mir-222 during storage in platelets prepared by platele...
متن کاملEffects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer
To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...
متن کاملInvestigating the Effects of Storage Time on Fats, Carbohydrates, Proteins, Taste, Color, and Texture Attributes of Roasted Pistachios by Two Fixed and Rotary Methods
Roasted pistachios are among the most delicious nuts in the world. In addition to their pleasant taste, they have significant nutritional and antioxidant effects. This study aims to evaluate the nutritional, sensory, color, and texture attributes of roasted pistachio nuts using fixed and rotary methods at 160 °C during three storage times of 0, 3, and 6 months, at the ambient temperature (20±2°...
متن کامللکوسیتها و عوارض انتقال خون: تاثیرات استفاده از فرآوردههای کملکوسیت در جلوگیری از عوارض ناشی از انتقال فرآوردههای خونی: مقاله مروری
Blood transfusion is commonly implemented to manage life and health-threatening conditions on a rapid and short-term basis. Over the years, ongoing technical advances have dramatically improved transfusion medicine to provide more safety and effectiveness. However, transfusion is still complicated with different adverse events that mainly induced by the presence of allogeneic leukocytes in the ...
متن کاملPlatelet Factor 3 Based-clotting Time Assay as a Quality Marker for Long-term Storage of Platelet Concentrates
Background: Platelets rapidly lose their qualities usually after 5 day of storage. Different standard methods have been recommended to check the quality of platelets during storage which some of them show better correlation with other quality markers during storage. The purpose of this study was to demonstrate if platelet factor 3 (PF3) assay could be an indicator of storage lesion and provide ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of immunological methods
دوره 206 1-2 شماره
صفحات -
تاریخ انتشار 1997